4.3 Command Communication
51
4.3.2
Explanation of Direct Control Commands
The following describe direct control commands in details.
Read operation control
This command specifies the data read timing.
[LON]
Trigger on
Command:
LON
Response: None
[LOFF]
Trigger off
Command:
LOFF
Response: None
• Even when the read operation is controlled with these commands, the BL-180
performs the same operation as with the trigger input (see page 10 to 12).
• “Trigger input: on” corresponds to
LON
, and “trigger input: off” corresponds to
LOFF
.
• The BL-180 starts read operation on receipt of
LON
and stops it on receipt of
LOFF
.
• When a bar code can be correctly read and the read data has already been
set, you need not send
LOFF
.
• The command characters can be freely changed (within 8 characters).
Test mode control
Starts or quits the test mode.
[TEST1]
Reading rate check
Command:
TEST1
Response: None
[TEST2]
Tact check
Command:
TEST2
Response: None
[QUIT]
Resetting test
Command:
QUIT
Response: None
• After using the test mode, be sure to reset it.
OK/NG output control
Directly turns on/off the OK/NG output.
This enables you to easily check wiring.
[OKON]
Turning the OK output on
Command:
OKON
Response:
OK
[NGON]
Turning the NG output on
Command:
NGON
Response:
OK
[ALLOFF]
Turning the OK/NG outputs off
Command:
ALLOFF
Response:
OK