12 other setting, 3 setup software operating procedure – KEYENCE BL-180 User Manual
Page 47

3.3 Setup Software Operating Procedure
39
3. When you select Default[:] for Partition mark and Intermediate delimiter,
these parameters are set as below:
When you select Custom, the following appears:
Then, you can enter the desired value from the keyboard (using one character
for the partition mark and 5 characters or less for the intermediate delimiter).
4. Input the Read error using the keyboard.
You can change the code as desired (within 8 characters).
Normally, you should use the default setting (ERROR). You can chose not to
send the read error by selecting a null value for the read error.
5. Click the Return button or press [ENTER] to return to the communication
setting screen.
Header string, delimeter --> Page 48
Partition mark --> Page 21
Intermediate delimiter --> Page 13
Read error --> Page 48
3.3.12
Other setting
1. Place the mouse cursor at the item to be changed and click it, or move to the
target item by pressing [TAB]. Then, change the setting using [Space].
2. By setting Bepper for OK/NG output, the beeper beeps to indicate reading
stability during the normal reading operation.
3. To set OK/NG output duration, enter the appropriate numeric value from the
keyboard. The setting range is from 1 to 255 (10 ms to 2.55 s).
4. To set Compare with, enter the preset data to be registered from the key-
board.
Usually, specify the data within 32 characters. If you are using CODE128 and
the start character is CODE-C, you can set the data using up to 64 characters.
5. Click the Return button or press [ENTER] to return to the main setting
screen.
STABILITY LED --> Page 19
OK/NG output duration --> Page 10
Preset data --> Page 20
Note
Note