4 command parameter list, Co mm u ni c a ting w ith t he fd -s s er ie s – KEYENCE DL-CL1 User Manual
Page 59

3-4 Command Parameter List
3-31
3
Co
mm
u
ni
c
a
ting
w
ith t
he FD
-S
s
er
ie
s
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-S) -
00
nn8F
Hysteresis
R/W
FD-SS02
001.0
000.0 to 200.0
FD-SF1(S)
0010
0000 to 1000
FD-SF1(F)
001.0
000.0 to 200.0
FD-SS2(S)
0010
0000 to 2000
FD-SS2(F)
001.0
000.0 to 200.0
FD-SF8(S)
00.10
00.00 to 08.00
FD-SF8(F)
0010
0000 to 2000
FD-SS20(S)
00.10
00.00 to 20.00
FD-SS20(F)
0010
0000 to 2000
nn90
Control Input
R/W
-
0
0: OFF
1: Bank change
2: Flow rate zero
3: Zero adjustment
4: Integration reset
nn91 to
nn96
System reserved
nn97
Power save mode
R/W
-
0
0: OFF
1: HALF
2: ALL
nn98 to
nn9C
System reserved
nn9D
Flow indicator
color
R/W
-
1
0: Red for ON, green for OFF
1: Green for ON, red for OFF
nn9E
to nn9F
System reserved
nnA0
Group5 entry
count
R
-
8
nnA1 to
nnA2
System reserved
nnA3
Flow direction
*11
R/W
-
0
0: std
1: rEv
nnA4
Integrated flow
quantity unit ("A"-
free version)
R/W
FD-SS02
3
0: Cannot be set / 1: 0.1 / 2: 1 / 3: 10 /
4: 100 / 5: 1000 / 6: Cannot be set
FD-SS2
0: Cannot be set / 1: Cannot be set /
2:1 / 3:10 / 4: 100 / 5: 1000 / 6: 10000
FD-SS20
0: 0.01 / 1: 0.1 / 2: 1 / 3: 10 / 4: 100 /
5: Cannot be set / 6: Cannot be set
nnA5 to
nnA6
System reserved
nnA7
Select volume/
mass flow rate
*11
R/W
-
1
0: Mass fl ow rate
1: Volume fl ow rate (specified density)
2: Volume fl ow rate (instantaneous
density)
nnA8
Specify focus
*11
R/W
-
0
0: OFF
1: ON
nnA9 to
nnBF
System reserved
nnC0
Group6 Entry
count
R
-
11
nnC1
Product Code
R
-
-
FD-SA*A: Main unit: 4014
FD-SA*A: Expansion unit: 4015
FD-SA*: Main unit: 4012
FD-SA*: Expansion unit: 4013
nnC2
Revision
R
-
-
0101h
Data
category
(HEX)
Data
number
(HEX)
Name
Description
Attribute
Sensor head
Default
value
Parameter range