3-2 Device Maps
3-7
3
Co
mm
u
ni
c
a
ting
 w
ith t
he FD
-S
s
er
ie
s
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-S) -
Number [n] denotes the first data memory number assigned to the DL-CL1.
*1
See
"Entering an External Input into a Sensor Amplifier" (page 3-17).
*2
See
"Reading Current Values (Instantaneous Flow Rate) from Sensor Amplifiers" (page 3-18).
*3
See
"Reading/Writing Settings or Status of a Sensor Amplifier" (page 3-21).
See
"Issuing a Motion Command to a Sensor Amplifier" (page 3-20).
*4
See
"Error information list" (page 3-8).
*5
See
"Command response list" (page 3-8).
*6
See
"Command Parameter List" (page 3-24).
Operating
mode
Device no.
(HEX)
Name
Communication
method
Description
Reading range
S
mall-memor
y mode
2
Monitor mode
1
RWr[n] + 04
 Integration 
reset input 
response 
*1
 Stores the integration reset input response of 
the sensor amplifi er.
The response is output by assigning sensor 
amplifi ers (ID 01 to ID 04) to bits 0 - 3. 
 0: Input OFF
1: Input ON 
RWr[n] + 05
 Flow rate 
hold reset 
input 
response 
*1
 Stores the fl ow rate hold reset input response 
of the sensor amplifi er.
The response is output by assigning sensor 
amplifi ers (ID 01 to ID 04) to bits 0 - 3. 
 0: Input OFF
1: Input ON 
RWr[n] + 06
 Zero 
adjustment 
input 
response 
*1
 Stores the zero adjustment input response of 
the sensor amplifi er. The response is output 
by assigning sensor amplifi ers (ID 01 to ID 
04) to bits 0 - 3. 
 0: Input OFF
1: Input ON 
RWr[n] + 07
 Current value 
property 
*2
 Used for reading the instantaneous fl ow rate 
value.
This property is output by assigning IDs (ID 
01 to ID 04) to bits 0 - 3.
The output occurs when the instantaneous 
fl ow rate value read from the sensor amplifi er 
is nonnumeric: "over" or "invalid." 
 0: Normal current 
value
1: "over" or "invalid 
(-----)" 
 RWr[n] 
+08 to 09 
(INT32) 
 Current 
value: box 1 
*2
 Used for reading the instantaneous fl ow rate 
value. The instantaneous fl ow rate value of the 
sensor amplifi er of the ID number specifi ed 
page number (RWw[n] + 08) is output.
Data type: INT32 (LITTLE) 
 Page 0: ID 01
Page 1: ID 04 
 RWr[n] 
+0A to 0B 
(INT32) 
 Current 
value: box 2 
*2
 Used for reading the instantaneous fl ow rate 
value.The instantaneous fl ow rate value of the 
sensor amplifi er of the ID number specifi ed 
page number (RWw[n] + 08) is output.
Data type: INT32 (LITTLE) 
 Page 0: ID 02
Page 1: (Not used) 
 RWr[n] 
+0C to 0D 
(INT32) 
 Current 
value: box 3 
*2
 Used for reading the instantaneous fl ow rate 
value.
The instantaneous fl ow rate value of the 
sensor amplifi er of the ID number specifi ed 
page number (RWw[n] + 08) is output. 
Data type: INT32 (LITTLE) 
 Page 0: ID 03
Page 1: (Not used) 
RWr[n] + 0E
 Temperature 
hold reset 
input 
response 
*1
 Stores the temperature hold reset input 
response of the sensor amplifi er.
The response is output by assigning sensor 
amplifi ers (ID 01 to ID 04) to bits 0 - 3. 
 0: Input OFF
1: Input ON 
RWr[n] + 0F (Not used)
-
--
--