beautypg.com

2 device maps, Co mm u ni c a ting w ith t he fd -s s er ie s – KEYENCE DL-CL1 User Manual

Page 35

background image

3-2 Device Maps

3-7

3

Co
mm

u

ni

c

a

ting
w

ith t
he FD

-S

s

er

ie

s

- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-S) -

Number [n] denotes the first data memory number assigned to the DL-CL1.

*1

See

"Entering an External Input into a Sensor Amplifier" (page 3-17).

*2

See

"Reading Current Values (Instantaneous Flow Rate) from Sensor Amplifiers" (page 3-18).

*3

See

"Reading/Writing Settings or Status of a Sensor Amplifier" (page 3-21).

See

"Issuing a Motion Command to a Sensor Amplifier" (page 3-20).

*4

See

"Error information list" (page 3-8).

*5

See

"Command response list" (page 3-8).

*6

See

"Command Parameter List" (page 3-24).

Operating

mode

Device no.

(HEX)

Name

Communication

method

Description

Reading range

S

mall-memor

y mode

2

Monitor mode

1

RWr[n] + 04

Integration
reset input
response

*1

Stores the integration reset input response of
the sensor amplifi er.
The response is output by assigning sensor
amplifi ers (ID 01 to ID 04) to bits 0 - 3.

0: Input OFF
1: Input ON

RWr[n] + 05

Flow rate
hold reset
input
response

*1

Stores the fl ow rate hold reset input response
of the sensor amplifi er.
The response is output by assigning sensor
amplifi ers (ID 01 to ID 04) to bits 0 - 3.

0: Input OFF
1: Input ON

RWr[n] + 06

Zero
adjustment
input
response

*1

Stores the zero adjustment input response of
the sensor amplifi er. The response is output
by assigning sensor amplifi ers (ID 01 to ID
04) to bits 0 - 3.

0: Input OFF
1: Input ON

RWr[n] + 07

Current value
property

*2

Used for reading the instantaneous fl ow rate
value.
This property is output by assigning IDs (ID
01 to ID 04) to bits 0 - 3.
The output occurs when the instantaneous
fl ow rate value read from the sensor amplifi er
is nonnumeric: "over" or "invalid."

0: Normal current
value
1: "over" or "invalid
(-----)"

RWr[n]
+08 to 09
(INT32)

Current
value: box 1

*2

Used for reading the instantaneous fl ow rate
value. The instantaneous fl ow rate value of the
sensor amplifi er of the ID number specifi ed
page number (RWw[n] + 08) is output.
Data type: INT32 (LITTLE)

Page 0: ID 01
Page 1: ID 04

RWr[n]
+0A to 0B
(INT32)

Current
value: box 2

*2

Used for reading the instantaneous fl ow rate
value.The instantaneous fl ow rate value of the
sensor amplifi er of the ID number specifi ed
page number (RWw[n] + 08) is output.
Data type: INT32 (LITTLE)

Page 0: ID 02
Page 1: (Not used)

RWr[n]
+0C to 0D
(INT32)

Current
value: box 3

*2

Used for reading the instantaneous fl ow rate
value.
The instantaneous fl ow rate value of the
sensor amplifi er of the ID number specifi ed
page number (RWw[n] + 08) is output.
Data type: INT32 (LITTLE)

Page 0: ID 03
Page 1: (Not used)

RWr[n] + 0E

Temperature
hold reset
input
response

*1

Stores the temperature hold reset input
response of the sensor amplifi er.
The response is output by assigning sensor
amplifi ers (ID 01 to ID 04) to bits 0 - 3.

0: Input OFF
1: Input ON

RWr[n] + 0F (Not used)

-

--

--