3-2 Device Maps
3-11
3
Co
mm
u
ni
c
a
ting
w
ith t
he FD
-S
s
er
ie
s
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-S) -
Operating
mode
Device no.
(HEX)
Name
Communication
method
Description
Reading range
Monitor mode
2
Full mode
1
Full mode
2
RX[n] + 40
to 49
(Not used)
-
--
--
RX[n] + 4F System reserved
-
Unusable
RX[n] + 50 Sensor ready
*2
Used when communicating under
handshake control program.
This is output when command execution is
ready.
0: In preparation
1: Ready
RX[n] + 51 Command complete
*2
Used when communicating under
handshake control program.
This is output when command execution is
complete.
0->1: Execution
complete
RX[n] + 52 Command error
*2
Used when communicating under
handshake control program.
This is output when an error occurs during
command execution.
0:No Error
1:Error
RX[n] + 53
::Current Value
Update Locked
-
This is output when current value update is
locked (current value update lock request
(RY[n] + 53) is enabled).
0: Update
enabled
1: Update locked
RX[n] + 54
to 5D
System reserved
-
Unusable
RX[n] + 60
to 63
(Not used)
-
-
-
RX[n] + 6F (Not used)
-
-
-
RY[n] + 70
to 73
Instantaneous fl ow
rate setting-1 (P1)
rewrite complete ID
01 to ID 04
*3
Used when rewriting a setting value.
This is output when the instantaneous fl ow
rate setting value 1 (P1) has been rewritten.
The output of each sensor amplifi er (ID 01
to ID 04) corresponds to each RX.
0->1: Rewrite
complete
RX[n] + 7F
Instantaneous fl ow
rate setting-1 (P1)
rewrite error
*3
Used when rewriting a setting value.
This is output if an error occurs with a
sensor amplifi er of any ID number during
rewriting of instantaneous fl ow rate setting
value 1 (P1).
0:No Error
1:Error
RX[n] + 80
to 83
Instantaneous fl ow
rate setting-2 (P2)
rewrite complete ID
01 to ID 04
*3
Used when rewriting a setting value.
This is output when the instantaneous fl ow
rate setting value 2 (P2) has been rewritten.
The output of each sensor amplifi er (ID 01
to ID 04) corresponds to each RX.
0->1: Rewrite
complete
RX[n] + 8F
Instantaneous fl ow
rate setting-2 (P2)
rewrite error
*3
Used when rewriting a setting value.
This is output if an error occurs with a
sensor amplifi er of any ID number during
rewriting of instantaneous fl ow rate setting
value 2 (P2).
0:No Error
1:Error
RX[n] + 90
to 93
Temperature upper
limit setting rewrite
complete ID 01 to
ID 04
*3
Used when rewriting a setting value.
This is output when the temperature upper
limit setting value has been rewritten. The
output of each sensor amplifi er (ID 01 to ID
04) corresponds to each RX.
0->1: Rewrite
complete
RX[n] + 9F
Temperature upper
limit rewrite error
*3
Used when rewriting a setting value.
This is output if an error occurs with a
sensor amplifi er of any ID number during
rewriting of temperature upper limit setting
value.
0:No Error
1:Error
RX[n] + A0
to A3
Temperature lower
limit setting rewrite
complete ID 01 to
ID 04
*3
Used when rewriting a setting value.
This is output when the temperature lower
limit setting value has been rewritten. The
output of each sensor amplifi er (ID 01 to ID
04) corresponds to each RX.
0->1: Rewrite
complete