2 device maps, Co mm u ni c a ting w ith t he fd -s s er ie s, Error information list – KEYENCE DL-CL1 User Manual
Page 36: Command response list

3-2 Device Maps
3-8
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-S) -
Co
mm
u
ni
c
a
ting
w
ith t
he FD
-S
s
er
ie
s
3
Error information list
* "nn" denotes the ID number in hexadecimal of sensor amplifier. (Example: 01h for ID01, ..., 04h for
ID04)
If there are multiple errors, the smallest error code is stored in the remote register.
Command response list
Error
Information
(HEX)
*
Description
Cause
Corrective action
0000
No error
-
-
0001
0002
0005
Initialization error
Error encountered during
initialization.
Check the number of connected
sensor amplifiers and the
connection to the sensor
amplifiers, and then cycle power.
If the error remain, contact your
nearest sales office.
0003
Model error
There is connected a
sensor amplifier of a
model incompatible with
the DL-CL1.
Connect a sensor amplifier of a
compatible model.
0004
Mixed connection error
A foreign sensor amplifier
(i.e., one that cannot be
intermixed) is connected.
Remove the foreign sensor
amplifier.
0006
Number-of-units error
More sensor amplifiers are
connected than are
permitted.
Observe the number of
connectable sensor amplifiers.
0007
Sensor-to-sensor communication error
An error exists in the
communication between
sensor amplifiers.
Check the connections of the
sensor amplifiers, and then turn
off the power and back on.
nn01
Error 1 for sensor amplifier of ID number nn
(Not used)
Refer to the FD-S series
instruction manual.
nn02
Error 2 for sensor amplifier of ID number nn
Head connection error
nn03
Error 3 for sensor amplifier of ID number nn
Overcurrent error
nn04
Error 4 for sensor amplifier of ID number nn
EEPROM Error
nn05
Error 5 for sensor amplifier of ID number nn
Dry water error
nn06
Error 6 for sensor amplifier of ID number nn
Backflow error
nn07
Error 7 for sensor amplifier of ID number nn
(Not used)
nn08
Error 8 for sensor amplifier of ID number nn
(Not used)
nn09
Error 9 for sensor amplifier of ID number nn
(Not used)
nn0A
Error 10 for sensor amplifier of ID number nn
Drive gain error
nn0B
Error 11 for sensor amplifier of ID number nn
Temperature low error
nn0C
Error 12 for sensor amplifier of ID number nn
Temperature high error
Response
(HEX)
Name
Description
0000
Successfully completed.
The command has been processed successfully.
0001
Command number error
The command number is out of range.
0002
Data category error
The data category value is out of range.
0003
ID number out of range
The ID number of sensor amplifier is out of range.
0004
Data number out of range
The data number is out of range.
0007
Sensor-to-sensor communication error
An error exists in the communication between sensors.
0008
Motion command access error
Cannot read/write to motion command data numbers.
0009
Motion command data number out of range
The data number of motion command is out of range.
000A
Motion command execution error
Failed to execute the motion command.
000B
Read inhibit
Write-only data number. Cannot be read.