- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-S) -

3-1

CC-Link Communication and Operating Modes

The DL-CL1 operates as a remote device station of a CC-Link system.
This section describes the data that the DL-CL1 can exchange through the CC-Link,
and available operating modes.

The DL-CL1's data is linked with the CC-Link maser station as shown below.

Through the link, the CC-Link master station is enabled to:

• Communicate the output signal, current value, and error status of sensor amplifiers

without the need of a ladder program.

• Use the remote input RX and remote output RY areas as handshake signals to

execute external inputs to, or change the setting values of, sensor amplifiers.

• Execute motion commands on sensor amplifiers.
• Directly read and write the parameters of sensor amplifiers. This capability gives

the ability to use functions that can be executed on sensor amplifiers.

Data Exchanged by Cyclic Transfer

(1) RX (Remote inputs)
(3) RWr (Remote registers)

(2) RY (Remote inputs)
(4) RWw (Remote registers)

Output

Current value

Error information

Read parameter

Request to change setting value

Changed setting value

External input

Write parameter

CC-Link master station

DL-CL1

Sensor amplifier

Output

Current value

Errror information

Output

Current value

Errror information

Output

Current value

Error information

Setting value

External input

Read/write parameters