HI 2151/30WC MANUAL
2-6
•
Response Time
1 millisecond after update
•
Isolation from Main Board
300 VAC or 450 VDC
•
Update
50 milliseconds (20 times/sec.)
•
Voltage Out
•
Range
0 - 5 VDC, 0-10 VDC (or reverse of these)
•
Max Current
5 ma (2 K ohm load @ 10 V)
•
Temp. Stability
10 ppm/C or 4 mV total from 30 to 120 degrees F
•
Current Out
•
Range
0 - 20 mA, 4-20 mA (or reverse of these)
•
Max Voltage
12 V allowing 0 - 600 ohm load at 20 mA
•
Mating Connector
6 pin Phoenix
Binary Coded Decimal
(BCD) (-B2)
•
Resolution
6 digits
•
Data Drive
15 LSTTL loads (6 mA total)
•
Print/Not Print Drive
10 LSTTL loads (4 mA)
•
Transmit Distance
50 feet (15.24 meters)
•
Cable
6" 40 pin right angle to 37 pin Dshell Connector. Use with -B6 and
-B7 Options