Hardy HI 2151/30WC Single-Scale Controller User Manual
Page 114

HI 2151/30WC MANUAL
7-16
SUB-CMD
Meaning
REM
Level status of the Remote Input connector (J2)
pins.
Bit
Remote Function Bit
Remote Function
01
Rate of change
10
Net
02
Totalizer
20
Lbs/Kgs
04
Display Hold
40
Tare
08
Option Hold
80
5. Q
The query command obtains a block of information as
follows:
SUB-CMD
Meaning
A.
Gross weight (6 bytes plus label)
B.
Net weight (6 bytes plus label)
C.
Peak gross value reached (6 bytes plus label)
D.
Internal counts (6 bytes)
E.
Total net accumulation (6 bytes plus label)
F.
Rate of change value (6 bytes plus label)
G.
Not Used (6 bytes set to 000000)
H.
Not Used (6 bytes set to 000000)
I.
LED status (4 bytes)
J.
Relay status (2 bytes)
Command
Meaning
F
Format the output data. Used to
configure data to be sent on a
TRANSMIT or PRINT request.
The SUB-CMD letters can be
issued in any combination or
order and are as follows:
SUB-CMD
Meaning
G
Gross
N
Net
T
Tare
R
ROC
S
Set point, Deadband, Preact
NOTE:
The last (6th) position is one of the following (must be accompanied by at least one of
the above SUB-CMDs):
-
Continuous printing.
P
Button on front panel "triggers" output.
NOTE:
The default FORMAT is GNTRSP.