4 x 2 drive system - (steel bed) – Cub Cadet 4 x 2 Big Country - Poly Bed & Steel Bed User Manual
Page 70
![background image](/manuals/656633/70/background.png)
4 X 2 Drive System - (Steel Bed)
66
12.11. Push the shift actuator into the case, and
remove it. See Figure 12.11.
12.12.Remove the seals from the case. There are
three on the left side housing: input shaft seal,
axle seal, and shift actuator seal. Do not re-use
the seals. See Figure 12.12.
12.13.Check the bearings in both sides of the housing
for any signs of damage (looseness, tightness,
discoloration, rough operation). If damage is
found, remove and discard the damaged bearing
or bearings.
NOTE: Only remove the bearings if they are to
be replaced. Do not re-use bearings that have
been removed.
12.14.The input shaft bearing can be driven out of the
housing. See Figure 12.14.
NOTE: The input shaft seal may be pushed
through as well. There is not a shoulder in the
bore.
12.15.The intermediate shaft bearing and the bearings
in the right side housing will require a blind bear-
ing puller and/or judicious application of heat.
See Figure 12.15.
Figure 12.11
Shift Actuator
Bore for
Shift Shaft
Figure 12.12
Axle
Seal
Input Shaft
Seal
Shift Actuator
Seal
Figure 12.14
Input Shaft
Bearing
Figure 12.15