Problem possible causes corrective action – Cub Cadet Fun Runner User Manual
Page 107
6-7
PROBLEM
POSSIBLE CAUSES
CORRECTIVE ACTION
Faulty controller.
readings should be less than 1 ohm.
Main Harness Key
Large Twist
Switch Connector
Lock Controller
Connector
Red wire Pin 1
to
Pin 30
Black wire Pin 2
to
Pin 31
White wire Pin 3
to
Pin 32
Green wire Pin 4
to
Pin 33
If wiring harness has continuity on all
four wires, then controller is most likely
faulty.
Faulty wiring harness.
If any of the four wires does not have
continuity, then repair or replace wiring
harness as needed.
Horn does not work.
No voltage to horn.
Faulty horn.
Faulty horn switch.
With ignition switch on, check voltage
between terminals on horn (12VDC)
when horn switch is depressed.
If voltage present and horn does not
sound, replace horn.
If voltage not present, check voltage at
horn switch between connector pins
with switch plugged in (about 12VDC
when horn switch not pressed and
should go to zero when switch is
pressed).
Voltage at horn switch does not go to
zero when switch is pressed. Replace