Fault Indication Table

Digits refer to Number of Pulses

NNT = Non Neutral Throttle

Fault

Indicator

Cause

Action to Take

Flt

Bat

Chg Tmp

Audio

Keyoff

1

Malfunction in key switch circuit

Test key switch and switch circuit (including jumper).

Cutback

flash

2@NNT Battery voltage approaching lower limit

Charge battery - retest

Low Battery

2

on

Battery low on initial startup

on

Battery low while driving

Throttle Sensor

3

3

Throttle sensor circuit malfunction on initial

Test throttle sensor and sensor circuits.

Fault

startup

4

1

Throttle sensor circuit malfunction while

driving

Non Neutral

4

4

Throttle depressed during initial startup

Return throttle to neutral position

Startup

Return to

2

2

Throttle returned to neutral

None

Neutral

Charge Inhibit

on

7

Startup with charger plugged in

Unplug charger to operate FunRunner

on

1@NNT Charger plugged in after startup

High Heat Sink

on

Heat sink temp high

Turn off vehicle and let cool. Inspect motor and all

Temp

cables and connections for signs of excessive

Excessive Sink

on

4@NNT Heat sink temp excessively high

current draw. Inspect brakes for dragging and look

Temp

for any cause of excessive load on motor. If

Shutdown Temp

flash 5@NNT Temp is high enough to cause shutdown

overheating continues, replace controller.

Current Limit

6

Current too high, shutdown (occurs after startup)

Inspect motor, cables, connections, and vehicle for

possible cause of high current. Pulling steep hills

could cause high current. If no problem, restart

and retest. Check motor current draw, if condition

continues and motor is ok, replace controller.

High Regen

7

Regen too high causing shutdown

If vehicle was driven down a steep hill at the time,

restart and retest. If condition continues during

normal operation, replace controller.

Bridge Fault

3

Powerpoint bridge fault at startup

Cutoff, inspect all components, wires, and

4

Lamps bridge fault at startup

connections. Restart. If condition continues

5

Bridge fault

replace controller.

6

(6 flashes on initial startup)

System

8

1

Drive Board system operational shutdown

Cutoff, inspect all components, wires, and

Operational

8

Interface Board system operational shutdown

connections. Restart. If condition continues

Shutdown

replace

controller.