5 normal mode commands, Normal mode commands – Rice Lake 820i Programmable Indicator/Controller - Installation Manual User Manual
Page 91

Serial Commands
87
9.1.5
Normal Mode Commands
The normal mode print commands (see Table 9-11) transmit data to the serial port on demand in either setup or
normal mode.
Table 9-11. Normal Mode Serial Commands
Command
Description
Values
CONSNUM
Set consecutive number
0–9 999 999
UID
Set unit ID
nnnnnnn
SD
Set date
MMDDYY, DDMMYY, YYMMDD, or YYDDMM. Enter six-digit
date using the year-month-day order specified for the
DATEFMT parameter, using only the last two digits of the
year.
ST
Set time
hhmm (enter using 24-hour format)
CONTRAST
Set display contrast
0–127
BACKLITE
Set display backlighting
ON, OFF
SX#n
Start serial port streaming
OK or ??
The port streaming parameter (EDP.STREAM#p) for the
streaming port must be set to LFT or INDUST before using
these commands.
An EX command sent while in setup mode does not take
effect until the indicator is returned to normal mode.
EX#n
Stop serial port streaming
SF#n
Transmit single frame of stream
Sends a single frame from scale n to the streaming port
RS
Reset system
Soft reset. Used to reset the indicator without resetting the
configuration to the factory defaults.
XA#n
Transmit accumulator value in displayed units
nnnnnn UU
XAP#n
Transmit accumulator value in primary units
XAS#n
Transmit accumulator value in secondary units
XAT#n
Transmit accumulator value in tertiary units
XG#n
Transmit gross weight in displayed units
nnnnnn UU
XGP#n
Transmit gross weight in primary units
XGS#n
Transmit gross weight in secondary units
XGT#n
Transmit gross weight in tertiary units
XN#n
Transmit net weight in displayed units
nnnnnn UU
XNP#n
Transmit net weight in primary units
XNS#n
Transmit net weight in secondary units
XNT#n
Transmit net weight in tertiary units
XT#n
Transmit tare weight in displayed units
nnnnnn UU
XTP#n
Transmit tare weight in primary units
XTS#n
Transmit tare weight in secondary units
XTT#n
Transmit tare weight in tertiary units
XE
Query system error conditions
nnnnn
See Section
91 for detailed information
about the XE command response format.