Descriptions in table – Rice Lake 820i Programmable Indicator/Controller - Installation Manual User Manual
Page 44

40
820i
Installation Manual
FEATURE Menu, REGULAT/INDUST Submenu
The INDUST setting of the REGULAT parameter allows customization of several tare, clear, and print functions
for use in non-legal-for-trade scale installations. See Section 10.2 on page 92 for more information about
regulatory mode functions.
SCALES SERIAL FEATURE
PFORMT SETPTS DIG
I/O ALGOUT VERS
REGULAT
SNPSHOT
DISPLAY
INDUST
SCALE
HTARE
NO
YES
ZTARE
NO
YES
KTARE
YES
NO
MTARE
REPLACE
REMOVE
NOTHING
NTARE
NO
YES
CTARE
YES
NO
PRTMOT
NO
YES
PRTPT
NO
YES
PRTHLD
NO
YES
HLDWGH
NO
YES
MOTWGH
NO
YES
CHILD ZT
NO
YES
NEGTOTAL
NO
YES
DISPLAY
AUDAGNCY
NTEP
CANADA
INDUST
NONE
OIML
OVRBASE
CALIB
SCALE
Figure 3-13. REGULAT / INDUST Submenu
FEATURE Menu, REGULAT / INDUST Submenu
Parameter
Choices
Description
Level 4, REGULAT / INDUST submenu
SNPSHOT
DISPLAY, SCALE
Display or Scale weight source.
HTARE
NO, YES
Allow tare in display hold
ZTARE
NO, YES
Remove tare on ZERO
KTARE
YES, NO
Always allow keyed tare
MTARE
REPLACE
REMOVE
NOTHING
Multiple tare action
NTARE
NO, YES
Allow negative or zero tare
CTARE
YES, NO
Allow CLEAR key to clear tare/accumulator
CHILD ZT
NO, YES
Clear child scales individually
NEGTOTAL
NO, YES
Allow total scale to display negative value
PRTMOT
NO, YES
Allow print while in motion
PRTPT
NO, YES
Add PT to keyed tare print
PRTHLD
NO, YES
Print during display hold
HLDWGH
NO, YES
Allow truck weighment during display hold
MOTWGH
NO, YES
Allow truck weighment in motion
OVRBASE
CALIB
SCALE
Sets an industrial scale to function like an OIML or NTEP scale (see Section
Table 3-9. REGULAT / INDUST Submenu Parameters