3 batch operations, Batch operations, Lb gross – Rice Lake 820i Programmable Indicator/Controller - Installation Manual User Manual
Page 81: Display or change assigned setpoints, Starts batch process, Is pressed again. pressing

Setpoints
77
8.3
Batch Operations
Softkeys can be configured to allow operator control
of batch operations from the
820i
front panel (see
Figure 8-10), Softkeys can be configured using
Revolution
, serial commands, or the FEATURE menu
(see Section 3.2.3 on page 35).
Figure 8-10. Batching Softkeys
Setpoint
Display or change assigned setpoints.
Batch Start
Starts batch process.
Batch Pause
Pauses an active batch and turns off
a l l d i g i t a l o u t p u t s e x c e p t t h o s e
associated with concurrent and timer
setpoints. Processing is suspended
until
Batch Start
is pressed again.
Pressing
Batch Start
resumes the
batch and re-energizes all digital
outputs turned off by the
Batch Pause.
Batch Reset
Stops and resets an active batch to the
beginning of the process.
Batch Stop
Stops an active batch and turns off all
associated digital outputs.
To prevent personal injury and equipment
damage, software-based interrupts must
always be supplemented by emergency stop
switches and other safety devices necessary
for the application.
Batching Switch
The batching switch option, PN 19369, comes as a
complete unit in an FRP enclosure, with legend plate,
locking stop switch (mushroom button), and a run/
start/abort 3-way switch.
Both switches are wired into the indicator’s digital I/O
terminal strip as shown in Figure 8-12. Each switch
uses a separate digital input.
Once cables and switches have been connected to the
indicator, use the setup switch to place the indicator in
setup mode. Use the DIG I/O menu (see Section 3.2.7
on page 44) to configure digital input and output
functions.
Figure 8-11. Batching Switch
When configuration is complete, exit setup mode.
Initialize the batch by turning the 3-way switch to
ABORT
, then unlock the STOP button (the STOP
button must be in the OUT position to allow the batch
process to run). The batching switch is now ready to
use.
If no digital input is assigned to BATRUN,
batching proceeds as if BATRUN were
always on: the batch will start when the
3-way switch is turned to RUN, but the
STOP mushroom button will not function.
Figure 8-12. Batching Switch Wiring Diagram Example
05/26/2006
11:08PM
2501
Scale
#1
lb
Gross
Setpoint Batch Start Batch Pause Batch Reset Batch Stop
Warning
Warning
RED
WHITE
BLACK
RED
BLACK
STOP/START MUSHROOM SWITCH
ABORT/RUN/START SWITCH
A
B
O
R
T
S
T
A
R
T
NO NC NC
NO NO
J5
+5VDC
GND
DIO1
DIO2
DIO3
DIO4
DIGITAL I/O
CPU BOARD
1 2 3 4 5 6 7 8 9 10
DIO5
DIO6
DIO7
DIO8
1
2
1
2
3
4
3
4
3
4