Option Cards
1-3 lists the available
820i
option cards. Most of
the listed option cards are be installed in the expansion
card slot, J6. USB, Ethernet, and fiber-optic interface
cards are installed in connector J1.
Table 1-3. Part Numbers for 820i Option Cards
Option Card
PN
Analog output card - Single
67602
Analog output card - Dual
103138
Dual serial port expansion card
67604
24-channel digital I/O expansion card
67601
1MB NV RAM memory expansion card
67600
Pulse input card
67603
Ethernet communications card
71986
EtherNet/IP communications card
87803
DeviceNet interface card
68541
Allen-Bradley Remote I/O interface card
68539
Profibus DP interface card
68540
Analog input card with thermocouple input
87697
USB interface card
93245
Ethernet interface card
77142
Fiber-optic interface card
77143
ControlNet interface card
103136
Relay Options
8-, 16-, and 24-channel relay racks are available for all
820i
systems. Relays require an external enclosure for
the relays. Consult factory for details.
DC Power Supplies
Two DC power supplies are available for mobile
820i
applications:
PN 97474, 9–36 VDC supply
PN 99480, 10–60 VDC supply
Outdoor Display
An optional display, PN 100758, is available for
applications requiring use of the
820i
in bright, sunlit
environments. Consult factory for details.
1.5
Summary of Changes
Changes to recent editions of this manual are listed
below:
Version 1.05
•
Added TOKENS parameters to the SERIAL
menu (see Section
30).
Version 1.04
•
Added new EDP command SF#n. See Section
9.1.5 for more information.
•
Added
numbering. See Section 6.1 on page 52 for
more information.
•
Added front panel token selections for
s t r e a m i n g . S e e F i g u r e 3 - 9 f o r m o r e
information.
•
Changed default PFORMAT port setting to
the new NONE selection. See Figure 3-15 on
page 40 for setting.
Version 1.02
•
Support for local/remote indicator configurations
provides function equivalent to a legal-for-trade
remote display with keypad for truck scale and
similar applications. See Section 10.4 on page 93
for more information.
•
The description for setting rate of change (ROC)
parameters has been changed. See Table 3-3 on
•
New values have been added to the STREAM
parameter on the SERIAL menu to allow
streaming of keypad events to another indicator
(4KEYS, KEYPAD) and, for the local/remote
function, to send the complete display image
(DISPLAY). See Section 3.2.2 for more
information.
•
New IMAGE parameter on the FEATURE menu
allows inversion of the display image
(blue-on-white or white-on-blue) for support of
the outdoor display option. See Section 3.2.3 for
more information.
•
Display and printing of audit trail information is
100.