Rice Lake 820i Programmable Indicator/Controller - Installation Manual User Manual
Page 87

Serial Commands
83
Command
Description
Values
SD
Set date
MMDDYY, DDMMYY, YYMMDD, or YYDDMM. Enter six-digit
date using the year-month-day order specified for the
DATEFMT parameter, using only the last two digits of the year.
ST
Set time
hhmm (enter using 24-hour format)
DATEFMT
Date format
MMDDYYYY, DDMMYYYY, YYYYMMDD, YYYYDDMM
DATESEP
Date separator
SLASH, DASH, SEMI
TIMEFMT
Time format
12HOUR, 24HOUR
TIMESEP
Time separator
COLON, COMMA
DECFMT
Decimal format
DOT, COMMA
DSPRATE
Display rate
1–80, in100-ms intervals
CONSNUM
Consecutive numbering
0–9999999
CONSTUP
Consecutive number start-up value 0–9999999
UID
Unit identifier
aaaaaaaa (up to 8 alphanumeric characters)
TRUCK
Truck in/out mode
OFF, MODE1, MODE2, MODE3, MODE4, MODE5, MODE6
ALIBI
Alibi data storage enable
OFF, ON
CFGPWD
Configuration password
0, 1–9999999
SPPWD
Setpoint password
0, 1–9999999
SK#1–SK#10
Softkey assignment
Blank, TimeDate, DspTar, DspAcc, DspROC, SetPt, BatStrt,
BatStop, BatPause, BatRst, WeighIn, WeighOut, TrkReg, UID,
Diagnostics, Alibi, SclSel, SKUD1–SKUD10
SKT#1–SKT#10
User-defined softkey text
—
KYBDLK
Keyboard lock (disable keypad)
OFF, ON
ZERONLY
Disable all keys except ZERO
OFF, ON
PROMPT#1–
PROMPT#60
Prompts/setpoint names
—
REGULAT
Regulatory compliance
NONE, OIML, NTEP, CANADA, INDUST
REG.SNPSHOT
Display or Scale weight source
DISPLAY, SCALE
REG.HTARE
Allow tare in display hold
NO, YES
REG.ZTARE
Remove tare on ZERO
NO, YES
REG.KTARE
Always allow keyed tare
NO, YES
REG.MTARE
Multiple tare action
REPLACE, REMOVE, NOTHING
REG.NTARE
Allow negative tare
NO, YES
REG.CTARE
Allow clear keyed tare
NO, YES
REG.CHILDZT
Clear child scales individually
NO, YES
REG.NEGTOTAL
Allow total scale to display negative
value
NO, YES
REG.PRTMOT
Allow print while in motion
NO, YES
REG.PRINTPT
Add PT to keyed tare print
NO, YES
REG.PRTHLD
Print during display hold
NO, YES
REG.HLDWGH
Allow weighment during display
hold
NO, YES
REG.MOTWGH
Allow weighment in motion
NO, YES
REGWORD
Regulatory word
GROSS, BRUTTO
CONTACT.COMPANY
Contact company name
company_name (up to 30 characters)
Table 9-5. FEATURE Serial Commands