Table – Rice Lake 820i Programmable Indicator/Controller - Installation Manual User Manual
Page 32

28
820i
Installation Manual
SCALES Menu, FORMAT Submenu, SPLIT
OFF
Parameter
Choices
Description
Level 4, FORMAT submenu
DECPT1
8888888
8888880
8888800
8.888888
88.88888
888.8888
8888.888
88888.88
888888.8
Decimal point location for first range or interval. Specifies the location of the decimal point or
dummy zeroes in the primary unit display. Value should be consistent with local legal
requirements.
DDIV1
1D
2D
5D
Display divisions for first range or interval. Selects the minimum division size for the primary
units displayed weight.
MAX1
50.00000
weight
Maximum weight for first range or interval.
DECPT2
888888.8
8888888
8888880
8888800
8.888888
88.88888
888.8888
8888.888
88888.88
Decimal point location for second range or interval. Specifies the location of the decimal
point or dummy zeroes in the primary unit display. Value should be consistent with local legal
requirements.
DDIV2
2D
5D
1D
Display divisions for second range or interval. Selects the minimum division size for the
primary units displayed weight.
MAX2
50.00000
weight
Maximum weight for second range or interval.
DECPT3
888888.8
8888888
8888880
8888800
8.888888
88.88888
888.8888
8888.888
88888.88
Decimal point location for third range or interval (SPLIT = 3RNG or 3INTVL only). Specifies
the location of the decimal point or dummy zeroes in the primary unit display. Value should
be consistent with local legal requirements.
DDIV3
2D
5D
1D
Display divisions for third range or interval (SPLIT = 3RNG or 3INTVL only). Selects the
minimum division size for the primary units displayed weight.
MAX3
50.00000
weight
Maximum weight for third range or interval (SPLIT = 3RNG or 3INTVL only).
Table 3-4. SCALES Menu, FORMAT Submenu Parameters, SPLIT
OFF