Operation

Model 2090 Multi-Device Controller

a small overshoot tolerance on this value, so, for example, a

current position of 99.5 will not cause an error when

switching to a polarization where the limit is 100.0.) Refer

to the section on “Editing Parameters” under

“Initialization” for information on checking or changing the

limits for the target polarization. In addition to a difference

in limits, the use of the Polarization Offset (

P4

) on a

standard tower could make it so that the current position at

the target polarization is outside the limits, even though the

displayed current position is within the target limits. See

above for a description of the polarization offset.

NOTE: In order to toggle the polarization of the tower from

the front panel, the display must be showing the current

position, and not either limit.

NOTE: While the 2090 will allow the tower to be polarized

while in motion, it is strongly recommended that the device

only be polarized while stationary. The added stress on the

tower mechanism and the antennas increases the chance of

damage to both. Always insure that the applied weight and

overhung load of the antenna are within the specifications

of the tower prior to polarizing.

62

© ETS-Lindgren– April, 2006

Revision G– P# 399199