ETS-Lindgren 2090 Controller User Manual
Page 154

Appendix B: Maintenance
Model 2090 Multi-Device Controller
e upgrade file from the program, “
Check
” as it performs
t,
possibly requiring a return to the factory for repair.
Should the upgrade fail for any reason, the motor base
operating firmware will be corrupt. As long as the
interruption occurred prior to the “
SAVE
” cycle, cycling
power on the motor base should restore it to normal
operation. If not, contact ETS-Lindgren for assistance.
Once the upgrade is complete, the motor base will restart,
booting into the new firmware. The Model 2090 will
typically indicate a communication lost (
E007
) error
momentarily until the motor base restores communication.
If the Model 2090 does not automatically recover
Press the “Program” button to initiate the upgrade process.
The flash upgrade file may contain additional
documentation encoded into it, which will be displayed
prior to starting the upgrade process. Once the upgrade is
initiated, the program will display the upgrade status in a
dialog and the Model 2090 will display the status of the
upgrade in the associated device window. The Model 2090
will display “
begin
” as the program negotiates with the
controller and motor base, “
FILE
” to indicate it is receiving
th
some functional checks on the motor base interface board,
“
prog
” as it sends the firmware data to the motor base,
“
Verif
” as it verifies the motor base received the file
properly, and “
SAVE
” as it commands the motor base to
store the data to EEPROM and restart. WARNING: Do
not cycle power or otherwise interrupt the firmware
download process, or memory corruption will resul
154
© ETS-Lindgren– April, 2006
Revision G– P# 399199