Using limit functions – ETS-Lindgren 2090 Controller User Manual
Page 58

Operation
Model 2090 Multi-Device Controller
TO STOP MOTION
To stop device motion, press the STOP key. The device
will decelerate (if equipped with variable speed control),
with the STOP motion indicator flashing to acknowledge
the key press, and then the motor drive will be disabled and
the STOP indicator will illuminate solid.
USING LIMIT FUNCTIONS
To set the lower/counterclockwise limit for the device
under control, press the DOWN/CCW key under LIMIT.
The indicator above this key will light. Set the limit by
pressing the INCRM and DECRM keys under LIMIT until
the desired limit is shown on the display. Then, press the
ENTER key. To set the upper/clockwise limit for the same
device press the UP/CW key under LIMIT. The indicator
light above this key will light. Set the limit by pressing the
INCRM and DECRM keys under LIMIT until the desired
limit is show on the display. Press the ENTER key. To
check the current position of the device under control press
the CURRENT POSITION key under LIMIT. The
indicator above this key will light and the device’s current
position will appear on the display.
NOTE: Two sets of upper and lower tower limits can be set
for horizontal and vertical antenna polarization. When
modifying these limits, keep in mind that only the limit of
the current polarization is being changed.
NOTE: The current position cannot be changed to a value
greater than the upper limit or less than the lower limit.
58
© ETS-Lindgren– April, 2006
Revision G– P# 399199