Error Message List

* = See module de-installation instructions on previous page.

Error Msg

Problem

Troubleshooting steps

ERR 12V

The circuit breaker on the KPA3 module may
be open. PA drops into bypass mode, fans
switch to level 2, and PA temp display mode is
not available.

Check for short from PA module’s 12V
line to ground. If there’s no short, try
resetting the circuit breaker. If there is a
short, remove the KPA3 module. Set
CONFIG:KPA3 to

PAI O ON

. While

waiting for a replacement, you can use the
K3 at reduced power.

ERR AT3

KAT3 not responding

*De-install the KAT3 module (see above).
If this eliminates the error message, the
KAT3 may be defective. You can
substitute a KANT3 antenna input module
temporarily, if available.

ERR BP1

No response from RF board BPF shift registers

*De-install option modules one at a time

ERR BP2

No response from KBPF3 option shift registers

*De-install KBPF3 on RF board

ERR BP3

No response from sub RX BPF shift registers

*De-install the KRX3 module, including
the SUBIN and SUBOUT boards

ERR BP4

No response from sub RX KBPF3 option

*De-install the KBPF3 module on KRX3

ERR DS1

No main DSP SPI echo

Reload DSP1 firmware

ERR DS2

Main DSP SPI echo not inverted

Reload DSP1 firmware

ERR DS3

No AUX DSP SPI echo

Reload DSP2 firmware. Note:
CONFIG:KRX3 must be set to

NOT

INS T

unless the KRX3 option is installed,

which includes the aux DSP module
(DSP2) and 2

nd

synthesizer.

ERR DS4

AUX DSP SPI echo not inverted

Reload DSP2 firmware. Note:
CONFIG:KRX3 must be set to

NOT

INS T

unless the KRX3 option is installed,

which includes the aux DSP module and
2

nd

synthesizer.

ERR DSE

Missing echo from a DSP command

Reload DSP1 firmware (and DSP2
firmware, if applicable).

ERR DSG

DSP internal gain error

Turn K3 off and back on to clear the error
condition. Please report this to Elecraft,
along with DSP internal error information.
(In the TECH MD menu entry, tap

1

and

2

to get main/aux DSP info, respectively.)

ERR DSX

Extended DSP command timeout

Reload DSP1 firmware (and DSP2
firmware, if applicable).

ERR DVR

Digital Voice Recorder not found

DVR module may be defective or
incorrectly installed, or the MCU or DSP
firmware may require updating.

ERR EE1

On-chip EEPROM read/write test failed

MCU may be defective (front panel). Try
re-loading MCU firmware first; then try
initializing parameters (pg. 66).