Band Outputs (BAND0-BAND3)

BAND0-3 provide band selection signals. Their
behavior is controlled by the CONFIG:KIO3 menu
entry (see below). Band data is based on VFO A.

Earlier K3s may require external pullup

resistors to 5 V on these lines, typically 2.2-10K.

In tables below, 0 = 0 VDC, and 1 = 5 VDC.

With CONFIG:KIO3 set to

NOR

, the BAND0-3

outputs are mapped based on the selected HF-6 m
band as shown below. On Transverter bands,
BAND0-3 will all be set to zero.

Band

BAND3

BAND2

BAND1

BAND0

160 m

0

0

0

1

80 m

0

0

1

0

60 m

0

0

0

0

40 m

0

0

1

1

30 m

0

1

0

0

20 m

0

1

0

1

17 m

0

1

1

0

15 m

0

1

1

1

12 m

1

0

0

0

10 m

1

0

0

1

6 m

1

0

1

0

If CONFIG:KIO3 is set to

TRN

, BAND0-3 reflect

the parameters of the CONFIG:XVn ADR menu
entry, as shown below. On HF-6 m they’re set to 0.
Addresses

INT . TRN0 -9

are used with the K3’s

internal 2-m transverter option (K144XV).

INT

TRN 0

sets all band outputs to 0, while

INT

TRN 1-9

have the same decodes as

TRN 1-9

.

Transverter addresses are also sent to Elecraft XV-
series transverters and the KRC2 via the AUXBUS
line. Note:

TRN 1-7

are sent as 1-7, but

TRN 8

and

TRN 9

are sent as 0.

ADR

BAND3

BAND2

BAND1

BAND0

TRN 1

0

0

0

1

TRN 2

0

0

1

0

TRN 3

0

0

1

1

TRN 4

0

1

0

0

TRN 5

0

1

0

1

TRN 6

0

1

1

0

TRN 7

0

1

1

1

TRN 8

1

0

0

0

TRN 9

1

0

0

1

With CONFIG:KIO3 set to

HF- TRN

, the

BAND0-3 outputs follow the

NOR

table when HF-

6 m bands are selected, and the

TRN

table when a

transverter band is selected.

Transverter Control

Normally, when the K3 is turned on, a 5-VDC logic
signal appears on ACC pin 7 (K3 ON). This could
be used with Elecraft XV transverters as an enable
signal (pin 8 of J6 on the transverter).

However, pin 7 can alternatively be configured as a
transmit inhibit input line for use in multi-
transmitter stations. (See TX INH, below.) In this
case it is not available as a power-on signal for
Elecraft transverters. Instead, the K3’s 12-VDC
switched output could be used for transverter ON.

For transverter keying, you can use KEYOUT-LP
signal (pin 10 of the ACC connector) or the KEY
OUT jack (RCA).

With KIO3 set to

TRN

or

HF- TRN

, the DIGOUT0

line (ACC, pin 6) will output 0 V when low power
mode is selected for the current transverter band
(CONFIG:XVn PWR). At all other times,
DIGOUT0 will be floating (Hi-Z).

The K3’s BAND0-2 outputs emulate the

Elecraft K60XV’s XVTR0-2 signals when
CONFIG:KIO3 is set to

TRN

or

HF- TRN

.

However, BAND0-2 on the K3 are open-drain
signals, while XVTR0-2 on the K60XV are TTL.

TX INH (Transmit Inhibit Signal)

Pin 7 of the ACC connector can be configured as a
transmit inhibit input by setting CONFIG:TX INH
to

LO= Inh

(or

HI= Inh

). Holding pin 7 low (or

high) will then prevent transmit. An external 2.2 to
10 K pull-up resistor (to 5 VDC) is required.

If TX INH is set to

OFF

, pin 7 reverts to its

default output function, K3 ON (see above).

Elecraft KRC2 Universal Band Decoder

An Elecraft KRC2 can be used with the K3 to
perform station switching functions; it includes sink
and source drivers for all bands. The KRC2 uses the
AUXBUS rather BAND0-3 (see CONFIG:KRC2
for 6-meter band mapping). Refer to the KRC2
instruction manual for more information.