Dell Latitude Xpi CD User Manual
Page 32

3-4
Dell Latitude XPi CD Service Manual
Decreasing
available
memory
Informational message
indicating memory is fail-
ing (usually preceded by
memory error message).
One or more DIMMs
faulty or improperly
seated.
Disk C: failed
initialization
Hard-disk drive failed to
initialize.
Hard-disk drive data
in System Setup
does not match
installed hard-disk
drive, or hard-disk
drive faulty.
System files missing
or corrupted.
Diskette drive 0
seek failure
Diskette read
failure
System cannot read dis-
kette in diskette drive.
Diskette faulty or
incorrectly inserted
in drive.
System Setup con-
tains incorrect
settings.
Diskette drive inter-
face loose or faulty.
Diskette drive faulty.
Diskette sub-
system reset
failed
Diskette subsystem failed
to respond to reset com-
mand from computer.
System board faulty.
Diskette write-
protected
Diskette is write-
protected, operation
cannot be completed.
Diskette write-
protected.
Drive not ready
The diskette may be
missing from or
improperly installed in
the diskette drive.
Defective or unfor-
matted diskette.
Error reading
PCMCIA card
Computer cannot identify
PC Card.
PC Card faulty,
improperly seated,
or improperly con-
figured. System
board faulty.
PC Card software
faulty or incorrectly
installed.
Table 3-2. System Error Messages
(Continued)
Message
Definition
Probable Causes