Configuring obfl, Displaying obfl information – Dell POWEREDGE M1000E User Manual
Page 1194
47-22
Cisco Catalyst Blade Switch 3130 and 3032 for Dell Software Configuration Guide
OL-13270-03
Chapter 47 Troubleshooting
Using On-Board Failure Logging
•
Uptime data—Time when a standalone switch or a stack member starts, the reason the switch
restarts, and the length of time the switch has been running since it last restarted
•
Voltage—System voltages of a standalone switch or a stack member
You should manually set the system clock or configure it by using Network Time Protocol (NTP).
When the switch is running, you can retrieve the OBFL data by using the show logging onboard
privileged EXEC commands. If the switch fails, contact your Cisco technical support representative to
find out how to retrieve the data.
When an OBFL-enabled switch is restarted, there is a 10-minute delay before logging of new data
begins.
Configuring OBFL
To enable OBFL, use the hw-module module [switch-number] logging onboard [message level level]
global configuration command. On stacking-capable switches, the range for switch-number is from 1
to 9. On nonstacking-capable switches, the switch number is always 1. Use the message level level
parameter to specify the severity of the hardware-related messages that the switch generates and stores
in the flash memory.
To copy the OBFL data to the local network or a specific file system, use the copy logging onboard
module stack-member destination privileged EXEC command.
Caution
We recommend that you do not disable OBFL and that you do not remove the data stored in the flash
memory.
To disable OBFL, use the no hw-module module [switch-number] logging onboard [message level]
global configuration command.
To clear all the OBFL data in the flash memory except for the uptime and CLI command information,
use the clear logging onboard privileged EXEC command.
In a switch stack, you can enable OBFL on a standalone switch or on all stack members by using the
hw-module module logging onboard [message level level] global configuration command.
For more information about the commands in this section, see the command reference for this release.
Displaying OBFL Information
To display the OBFL information, use one or more of the privileged EXEC commands in
Table 47-3
Commands for Displaying OBFL Information
Command
Purpose
show logging onboard [module
[switch-number]] clilog
Displays the OBFL CLI commands that were entered on a standalone
switch or the specified stack members.
show logging onboard [module
[switch-number]] environment
Display the UDI information for a standalone switch or the specified
stack members and for all the connected FRU devices: the PID, the VID,
and the serial number.
show logging onboard [module
[switch-number]] message
Display the hardware-related messages generated by a standalone switch
or the specified stack members.