Table 5-7, Or during the, Open request (see – Cabletron Systems CSMIM-T1 User Manual
Page 96: Table 5-8

Chapter 5: Troubleshooting Procedures
5-12
CSMIM-T1 Hardware Installation Guide
Table 5-7
Errors from Last Read Request
Table 5-8
Errors from Last Open Request
Error
Description
Msgs with wrong size
The correct host responded to the Read Request, but
the data size is incorrect.
ERPC layer errors
See
.
Aborts rx’d
The host’s BFS transmitted an abort in response to the
CSMIM-T1’s
Read Request. Run erpcd –D on the host
to obtain more information.
Error
Description
ARP errors
Address Resolution Protocol (ARP) errors indicate that the
CSMIM-T1 is configured to boot from a specified host, but
the host would not transmit its Ethernet address to the
CSMIM-T1. Possibly, the CSMIM-T1 configuration
includes the wrong IP encapsulation.
ERPC layer errors
See
Aborts rx’d
The host’s BFS transmitted an abort in response to the
CSMIM-T1’s
Open Request. This often means that the
requested file does not exist on that server. Run erpcd –D
on the host to obtain more information.