beautypg.com

Table 5-7, Or during the, Open request (see – Cabletron Systems CSMIM-T1 User Manual

Page 96: Table 5-8

background image

Chapter 5: Troubleshooting Procedures

5-12

CSMIM-T1 Hardware Installation Guide

Table 5-7

Errors from Last Read Request

Table 5-8

Errors from Last Open Request

Error

Description

Msgs with wrong size

The correct host responded to the Read Request, but
the data size is incorrect.

ERPC layer errors

See

Table 5-6

.

Aborts rx’d

The host’s BFS transmitted an abort in response to the
CSMIM-T1’s

Read Request. Run erpcd –D on the host

to obtain more information.

Error

Description

ARP errors

Address Resolution Protocol (ARP) errors indicate that the
CSMIM-T1 is configured to boot from a specified host, but
the host would not transmit its Ethernet address to the
CSMIM-T1. Possibly, the CSMIM-T1 configuration
includes the wrong IP encapsulation.

ERPC layer errors

See

Table 5-6

Aborts rx’d

The host’s BFS transmitted an abort in response to the
CSMIM-T1’s

Open Request. This often means that the

requested file does not exist on that server. Run erpcd –D
on the host to obtain more information.