PARAMETER DESCRIPTIONS

The CSMIM-T1 software comes with the following new parameters:

alarmsyslog

This T-1 parameter enables or disables the T-1 alarm event syslogs. A Y
enables this parameter, an N disables it. The default is Y.

bypass

This T-1 parameter is used to remove the T-1 engine from the network.
When bypass is set to Y, the T1 engine is off-line and the T1 Network
Interface (T1NI) and the T1 Drop and Insert Interface (T1DII) are
physically isolated from the T-1 engine. When bypass is set to Y, the T-1
engine has no effect on the T-1 circuit. When bypass is set to N, the T-1
engine is attached to both the T1NI and the T1DII. The default is Y.

tni_line_code

Sets or displays parameter setting as ami or b8zs. These
values represent the line code used on the T1 Network
Interface.

tni_ones_density

Sets or displays the T1 Network Interface ones density
setting as on or off.

tdi_distance

Sets or displays an integer from 0 to 655 that represents
the length of the cable from the T1 Drop/Insert Interface to
the PBX or other equipment.

tdi_framing

Sets or displays the superframe format used on the T1
Drop/Insert Interface as d4 (superframe) or esf (extended
superframe). The default is esf.

tdi_line_code

Sets or displays the T1 Drop/Insert Interface line code
setting as either ami or b8zs. The default is b8zs.

Keyword