Chapter 3: ROM Monitor Commands

3-4

CSMIM-T1 Hardware Installation Guide

The addr command display looks like this:

The addr -d command display looks like this:

The CSMIM-T1 must have an Internet (IP) address in its memory before
it can load its operational image across the Ethernet via the IP protocol.
Therefore, you must enter the IP address before booting the CSMIM-T1
from a UNIX load host. If you do not define an IP address for the Remote
Annex, it will attempt to learn the address using BOOTP or RARP. If you

monitor:: addr

Enter Internet address []:: 192.9.200.214

Internet address: 192.9.200.214

Enter Subnet mask [255.255.0.0]::

Enter Broadcast address [0.0.0.0]:: 192.9.200.0

Broadcast address: 192.9.200.0

Enter Preferred Load Host address []:: 192.9.200.88

Preferred Load Host address: 192.9.200.88

Enter Preferred Dump Host address [0.0.0.0]:: 192.9.200.88

Preferred Dump Host address: 192.9.200.88

Enter Load/Dump Gateway address []:: 192.9.200.

Load/Dump Gateway address: 192.9.200.88

Select type of IP packet encapsulation (ieee802/ethernet)

[]::

Load Broadcast Y/N [Y]::

monitor:: addr -d

Ethernet address (hex): 00-80-2D-00-C6-1E

Internet address: 192.9.200.214

Subnet mask: 255.255.0.0

Broadcast address: 192.9.200.0

Preferred Load Host address: 192.9.200.88

Preferred Dump Host address: 192.9.200.88

Load/Dump Gateway address: 192.9.200.10

Type of IP packet encapsulation:

Load Broadcast: Y