beautypg.com

5 set t-1 parameters example, Set t-1 parameters example -13 – Cabletron Systems CSMIM-T1 User Manual

Page 81

background image

Set T-1 Parameters Example

CSMIM-T1 Hardware Installation Guide

4-13

tni_ones_density

This T-1 parameter is used to defeat the CSMIM-T1 ones density monitor.
The T-1 engine has a built in ones density monitor that will provide the
network with the correct number of one pulses. The ones density monitor
does the following:

1.

The monitor does not allow the CSMIM-T1 to transmit more than
fifteen consecutive zeros.

2.

The monitor ensures that the CSMIM-T1 has at least N ones in every
time window of 8X(N+1) bits, where N=1 to 23.

This parameter has an on and an off setting. This parameter should be set
to on when using AMI coding. The default is

off

.

4.5

SET T-1 PARAMETERS EXAMPLE

The following is an example of the

show

,

set

, and

reset

commands and

provides actual screens to reference while proceeding. What we have
done is show the T-1 info screen, set the T-1 bypass to N allowing the T-1
line to interface with the module, change the loop start setting to wink
start, and reset the software at the appropriate times. This is an actual
example of how to make the T-1 module functional.

annex: su

Password:

annex# ad

ANNEX3-UX R10.1, 24 async ports, 0 printer ports

admin: show t1

Channelized T1 Generic Parameters

alarmsyslog: Y

bypass: Y

t1_info: “”

tni_clock: loop

tni_line_buildout: 0dB

tni_ones_density: off

tni_framing: esf

tni_line_code: b8zs

tni_esf_fdl: att

tni_circuit_id: “”

tdi_framing: esf

tdi_line_code: b8zs

tdi_distance: 0

admin: set t1 bypass n

You may need to reset the appropriate port, Annex subsystem or

reboot the Annex for changes to take effect.

admin: res t1 soft

admin: sho t1 ds0