beautypg.com

Rs-485 hardware – Cooper Instruments & Systems DFI INFINITY Digital Force Indicator/Controller User Manual

Page 8

background image

Table 2.1. Meter Hookup (RS-232) to the Computer

METER
(DCE)

COMPUTER
(DTE)

PIN SIGNAL/
FUNCTION

RJ-11 RJ-12

D9

D25

RTS, meter from computer

1

2

7

4

TX, meter = RX, computer

2

3

2

3

RX, meter = TX, computer

3

4

3

2

Return 4

5

5

7

NC (not connected)

1,6

(all others)


Table 2.2 shows the pin connection assignments between the RS-232 connection on the meter and the 9-pin or
25-pin “D” connectors of your printer.

Table 2.2. Meter Hookup (RS-232) to the Printer

METER

PIN SIGNAL/
FUNCTION RJ-11

RJ-12

PRINTER
FUNCTIONS

RTS, meter

1

2

Data Terminal Ready (DTR)

TX,

meter

2 3 Received

Data

(RXD)

RX, meter

3

4

Not Connected

Return

4 5 Signal

Return

NC (not connected)

1,6

2.3 RS-485

Hardware

INSTALLATION: The RS-485 card (refer to Figure 2-5A, or if you have an older option card refer to Figure 2-
5B
) is the same size and plugs in the same ways as the RS-232 card, refer to Section 2.2.

Figure 2-5A. RS-485 Option Board

JUMPER

RS485
HALF DUPLEX

RS485
FULL DUPLEX

S1-A OPEN

OPEN

S1-B CLOSE

OPEN

S2-A CLOSE

CLOSE

S3-A *

*

CF 125 INFINITY SC GUIDE

4