Manning strickler coefficient table – ADS Environmental Services Portable FlowShark Pulse QR 775006 A2 User Manual
Page 197

A P P E N D I X C
Manning Strickler Coefficient Table
Consistency of channel wall
M in m1/3/s
k in mm
s
m
oot
h
glass, PMMA, polished metal surfaces
> 100
0...0.003
plastic (PVC, PE)
new steel plate with protective coating;
smoothened cement plaster
≥ 100
0.05
0.03...0.06
m
oder
at
el
y
r
ough
asphalt coated steel plate;
concrete from steel or vacuum formwork, no joints, carefully
smoothened;
planed wood, joint-free, new;
asbestos cement, new
90...100
0.1...0.3
smoothened concrete, smooth finish
planed wood, well-joint
85...90
0.4
0.6
concrete, good formwork, high cement contents
80
0.8
rough
non-planed wood; concrete pipes
75
1.5
hard-burned bricks, carefully joint;
well-manufactured ashlar facing;
concrete from joint-free wooden formwork
70...75
1.5...2.0
rolling-cast asphalt finish
70
2
well-manufactured ashlar masonry;
moderately incrusted steel pipes;
non-finished concrete, wooden formwork;
squared stones; old and swelled wood;
cement walls
65...70
3
non-finished concrete; old wooden formwork;
brickwork, no joints, finished;
quarrystone walls; less accurate
soil material, smooth (fine-grained)
60
6