6-60 ADS Portable FlowShark Pulse Manual
h_crit min
Flow velocities falling below h_crit will not be calculated and, therefore, will be set to
0 (zero).
1
h_critical
2
h_crit min
3
Range of automatic Q/h relationship
4
Determination of application coefficient
Determining v_crit
Auto discharge curve
Depending on the selected setting, the unit will verify and correct (if necessary) the
values entered during the next measurement interval (automatic YES). Another
available option is for the unit to use only the values entered in the menu for Manning
Strickler, manual, or Assistant (automatic NO).
Auto discharge curve
Avoid backwater up to 0.5 inches (12 mm) deep when using the
Automatic YES option.