ClearOne Converge Pro User Manual
Page 254
250 technical Services: 800-283-5936
Converge Sr 1212: Port a (Female DB-25)
Pin #
user Definable
Control/Status
Default Description
1
Y
Control (input)
2
Y
Status (output)
3
Y
Control (input)
Mute All Mics toggle
4
Y
Status (output)
Status of Mute All Mics
5
Y
Control (input)
Mute output 9 toggle
6
Y
Status (output)
Status of Mute output 9
7
Y
Control (input)
Mute output 10 toggle
8
Y
Status (output)
Status of Mute output 10
9
Y
Control (input)
Mute output 11 toggle
10
Y
Status (output)
Status of Mute output 11
11
Y
Control (input)
Mute output 12 toggle
12
Y
Status (output)
Status of Mute output 12
13
Y
Control (input)
Volume up output 1 (1 dB)
14
Y
Status (output)
15
Y
Control (input)
Volume Down output 1 (1 dB)
16
Y
Status (output)
17
n
Status (output)
Microphone 1 Gate Status
18
n
Status (output)
Microphone 2 Gate Status
19
n
Status (output)
Microphone 3 Gate Status
20
n
Status (output)
Microphone 4 Gate Status
21
n
Status (output)
Microphone 5 Gate Status
22
n
Status (output)
Microphone 6 Gate Status
23
n
Status (output)
Microphone 7 Gate Status
24
n
Status (output)
Microphone 8 Gate Status
25
nA
nA
Ground