Appendix A: Serial Commands 231

mTRX – Matrix Routing

This command selects/reports the matrix routing of an input to an output.

Command Form

: DEVICE mTRX [Value]

argument

Type

size

values

Units

Source Channel

Channel

1

See Groups and channels

Source Group

Group

1

1, 3, 5, 6, 7, 12, 17
(i, m, p, e, l, F, r)

destination Channel

Channel

1

See Groups and channels

destination Group

Group

1

2, 5, 6, 12, 16, 20
(o, p, e, F, T, B)

Value

unsigned integer

4

0 = Cross point off
1 = Cross point on (not Valid for mic
Sources)
2 = Toggle (not Valid for mic Sources)
3 = non Gated (mic Sources only)
4 = Gated (mic Sources only)
5 = pre-AeC (mic Sources only)
6 = routing prohibited (Cross point is
off and may not be turned on)
(null to query in text)

mTRXcleaR – Clear Matrix

Clears the enTire matrix for the unit. There is no query for this command.

Command Form

:

DEVICE mTRXcleaR

no arguments

mTRXlvl – Matrix Attenuation Adjust

This command selects/reports the matrix level at the cross point.

Command Form

:

DEVICE mTRXlvl [Value] [A/r]

argument

Type

size

values

Units

Source Channel

Channel

1

See Groups and channels

Source Group

Group

1

1, 3, 5, 6, 7, 12, 17
(i, m, p, e, l, F, r)

destination Channel

Channel

1

See Groups and channels

destination Group

Group

1

2, 5, 6, 12, 16,
(o, p, e, F, T,)

Value

Signed Float

4

-99.00 – 99.00 **
(null to query in text)

dB

Absol / rel

0

A = Absolute
r = relative
null = relative

noTe: Values indicate entry range only. Actual internal range of the matrix attenuation is from –60

to +12dB, and absolute values are limited to the internal gain range.