ClearOne Converge Pro User Manual
Page 235
![background image](/manuals/598132/235/background.png)
Appendix A: Serial Commands 231
mTRX – Matrix Routing
This command selects/reports the matrix routing of an input to an output.
Command Form
: DEVICE mTRX
argument
Type
size
values
Units
Source Channel
Channel
1
See Groups and channels
Source Group
Group
1
1, 3, 5, 6, 7, 12, 17
(i, m, p, e, l, F, r)
destination Channel
Channel
1
See Groups and channels
destination Group
Group
1
2, 5, 6, 12, 16, 20
(o, p, e, F, T, B)
Value
unsigned integer
4
0 = Cross point off
1 = Cross point on (not Valid for mic
Sources)
2 = Toggle (not Valid for mic Sources)
3 = non Gated (mic Sources only)
4 = Gated (mic Sources only)
5 = pre-AeC (mic Sources only)
6 = routing prohibited (Cross point is
off and may not be turned on)
(null to query in text)
mTRXcleaR – Clear Matrix
Clears the enTire matrix for the unit. There is no query for this command.
Command Form
:
DEVICE mTRXcleaR
no arguments
mTRXlvl – Matrix Attenuation Adjust
This command selects/reports the matrix level at the cross point.
Command Form
:
DEVICE mTRXlvl
argument
Type
size
values
Units
Source Channel
Channel
1
See Groups and channels
Source Group
Group
1
1, 3, 5, 6, 7, 12, 17
(i, m, p, e, l, F, r)
destination Channel
Channel
1
See Groups and channels
destination Group
Group
1
2, 5, 6, 12, 16,
(o, p, e, F, T,)
Value
Signed Float
4
-99.00 – 99.00 **
(null to query in text)
dB
Absol / rel
0
A = Absolute
r = relative
null = relative
noTe: Values indicate entry range only. Actual internal range of the matrix attenuation is from –60
to +12dB, and absolute values are limited to the internal gain range.