Appendix A: Serial Commands 213

aGcseT – Automatic Gain Control Adjust

This command selects/reports the settings of the Automatic Gain Control.

Command Form

: DEVICE aGcseT [Threshold Target Attack Gain]

argument

Type

size

values

Units

Channel

Channel

1

See Groups and channels

Group

Group

1

1, 3, 7 (i, m, l)

Threshold

Signed integer

1

-50 – 0
(null to query in text)

dB

Target

Signed integer

1

-30 – 20

dB

response
Time

unsigned Float

2

0.10 – 10.00

S

Gain

unsigned Float

2

0.00 – 18.00

dB

amblvl – Ambient Level Adjust

This command selects/reports the ambient level.

Command Form

: DEVICE amblvl [Value]

argument Type

size

values

Units

Channel

Channel

1

See Groups and channels

Group

Group

1

3 (m)

Value

Signed Float

2

-80.00 – 0.00
(null to query in text)

dB

amXdUeT – Use AMX Duet Discovery

This command sets and reports the status of Amx duet discovery.

Command Form

: DEVICE amXdUeT [Value]

argument Type

size

values

Units

Value

unsigned integer

4

0 = off
1 = on
2 = toggle
(null to query in text)

aUdiomasTeR – Expansion Bus Audio Master Mode

This command reports the mode of the unit for control of the expansion bus audio.

Command Form

: DEVICE aUdiomasTeR [Value]

argument Type

size

values

Units

Value

unsigned integer

4

1 = master
2 = Slave
(null to query in text)

baUd – Baud Rate

This command selects/reports the baud rate of the serial port.

Command Form

: DEVICE baUd [Value]

argument Type

size

values

Units

Value

unsigned integer

4

9600, 19200, 38400, 57600, 115200
(null to query in text)