beautypg.com

ClearOne Converge Pro User Manual

Page 222

background image

218 Technical Services: 800-283-5936

deviceType – Sets the Type of a Connected Device

This command enables / disables or reports the current type of device connected to an input or output.

Command Form

: DEVICE deviceType [Value]

argument Type

size

values

Units

Channel

Channel

1

See Groups and channels

Group

Group

1

1, 2, 3, 7 (i, o, m, l)

Value

unsigned integer

2

(null to query in text)

dFlTm – Default Meter

This command selects/reports the setting of the default meter on the front panel.

Command Form

: DEVICE dFlTm [Channel Group position]

argument Type

size

values

Units

Channel

Channel

1

See Groups and channels
(null to query in text)

Group

Group

1

1, 2, 3, 7, 16, 17 (i, o, m, l, T, r)

position

meter Type

2

1 – 4, as applicable for group
See meter Type definitions

dial – DTMF Dialing

This command dials a dTmF sequence or reports back the last sequence dialed.

Command Form

: DEVICE dial [number]

argument

Type

size

values

Units

Channel

Channel

1

See Groups and channels

Group

Group

1

17 (r)

reserved

2

0

number

String

40

1 – 40 Chars of ‘0’ – ‘9’, ‘A’ – ‘d’, ‘*’, ‘#’, ‘,’
(null to query last number dialed in text)

did – Device ID

This command reports the device id. This command is read only except through the front panel.

Command Form

: DEVICE did [Value]

argument Type

size

values

Units

Value

unsigned integer

4

See Type and device ids
(null sent in text, Value returned)

dspveR – DSP Version

This command reports the version of the dSp code in the unit. This command is read only.

Command Form

: DEVICE dspveR [Time/date]

argument

Type

size

values

Units

Value

unsigned integer

4

0 for Host
1 – 8 for Satellite
9 for Telco

Time / date

String

16

(null to query in text)