beautypg.com

ClearOne Converge Pro User Manual

Page 219

background image

Appendix A: Serial Commands 215

cleaReFFecT – Clear Effect Wide Band Telco Emulation

This command enables / disables or reports the current status of the clear effect.

Command Form

: DEVICE cleaReFFecT [Value]

argument Type

size

values

Units

Channel

Channel

1

See Groups and channels

Group

Group

1

17 (r)

Value

unsigned integer

2

0 = off
1 = on
2 = Toggle
(null to query in text)

clocK – Clock Set

This command sets or reports the current time.

Command Form

: DEVICE clocK [date month Year Hours minutes Seconds day]

argument Type

size

values

Units

date

unsigned integer

1

1 – 31

month

unsigned integer

1

1 – 12

Year

unsigned integer

2

2000 – 2099
(null to Query in Text)

Hours

unsigned integer

1

00 – 23

minutes

unsigned integer

1

00 – 59

Seconds

unsigned integer

1

00 – 59

day of
Week

unsigned integer

1

1 = Sunday
2 = monday
3 = Tuesday
4 = Wednesday
5 = Thursday
6 = Friday
7 = Saturday

compRess – Compressor Adjust

This command selects/reports the settings of the compressor.

Command Form

: DEVICE compRess [Threshold ratio Attack release Gain]

argument

Type

size

values

Units

Channel

Channel

1

See Groups and channels

Group

Group

1

5 (p)

Threshold

Signed integer

1

-60 – 20
(null to query in text)

dB

ratio

unsigned integer

1

1 – 20

Attack

unsigned Float

2

0.00 – 100.00

ms

release

unsigned integer

2

100 – 2000

ms

Gain

unsigned Float

4

0.00 – 20.00

dB