beautypg.com

ClearOne Converge Pro User Manual

Page 234

background image

230 Technical Services: 800-283-5936

min – Minimum Gain Setting

This command changes or reports back the minimum gain setting for a channel.

Command Form

: DEVICE min [Value]

argument Type

size

values

Units

Channel

Channel

1

See Groups and channels

Group

Group

1

1, 2, 3, 5, 7, 12, 16, 17 (i, o, m, p, l, F, T, r)

Value

Signed Float

2

-65.00 – 20.00
(null to query in text)

dB

minmaX – Minimum and Maximum Gain Setting

This command changes or reports back the minimum and maximum gain setting for a channel.

Command Form

: DEVICE minmaX [min max]

argument Type

size

values

Units

Channel

Channel

1

See Groups and channels

Group

Group

1

1, 2, 3, 5, 7, 12, 16, 17 (i, o, m, p, l, F, T, r)

min

Signed Float

2

-65.00 – 20.00
(null to query in text)

dB

max

Signed Float

4

-65.00 – 20.00

dB

mline – Mic / Line Coarse Gain Setting

This command selects/reports the setting of coarse gain.

Command Form

: DEVICE mline [Value]

argument Type

size

values

Units

Channel

Channel

1

See Groups and channels

Group

Group

1

3 (m)

Value

unsigned integer

2

0 = 0 dB
7 = 7 dB
14 = 14 dB
21 = 21 dB
28 = 28 dB
35 = 35 dB
41 = 41 dB
50 = 50 dB
56 = 56 dB
(null to query in text)
(no other values are valid and accepted)

mmaX – Maximum Number of Microphones

This command selects/reports the maximum number of microphones for a Gating Group.

Command Form

: DEVICE mmaX [Value]

argument Type

size

values

Units

Channel

Channel

1

See Groups and channels

Group

Group

1

4 (G)

Value

unsigned integer

2

0 = unlimited
1 - 8 = maximum # of mics
(null to query in text)