ClearOne Converge Pro User Manual
Page 234
230 Technical Services: 800-283-5936
min – Minimum Gain Setting
This command changes or reports back the minimum gain setting for a channel.
Command Form
: DEVICE min
argument Type
size
values
Units
Channel
Channel
1
See Groups and channels
Group
Group
1
1, 2, 3, 5, 7, 12, 16, 17 (i, o, m, p, l, F, T, r)
Value
Signed Float
2
-65.00 – 20.00
(null to query in text)
dB
minmaX – Minimum and Maximum Gain Setting
This command changes or reports back the minimum and maximum gain setting for a channel.
Command Form
: DEVICE minmaX
argument Type
size
values
Units
Channel
Channel
1
See Groups and channels
Group
Group
1
1, 2, 3, 5, 7, 12, 16, 17 (i, o, m, p, l, F, T, r)
min
Signed Float
2
-65.00 – 20.00
(null to query in text)
dB
max
Signed Float
4
-65.00 – 20.00
dB
mline – Mic / Line Coarse Gain Setting
This command selects/reports the setting of coarse gain.
Command Form
: DEVICE mline
argument Type
size
values
Units
Channel
Channel
1
See Groups and channels
Group
Group
1
3 (m)
Value
unsigned integer
2
0 = 0 dB
7 = 7 dB
14 = 14 dB
21 = 21 dB
28 = 28 dB
35 = 35 dB
41 = 41 dB
50 = 50 dB
56 = 56 dB
(null to query in text)
(no other values are valid and accepted)
mmaX – Maximum Number of Microphones
This command selects/reports the maximum number of microphones for a Gating Group.
Command Form
: DEVICE mmaX
argument Type
size
values
Units
Channel
Channel
1
See Groups and channels
Group
Group
1
4 (G)
Value
unsigned integer
2
0 = unlimited
1 - 8 = maximum # of mics
(null to query in text)