ClearOne Converge Pro User Manual
Page 233

Appendix A: Serial Commands 229
macRo – Macro Execution/Reporting
This command executes a specified macro or reports the last macro executed.
Command Form
: DEVICE macRo [Value]
argument Type
size
values
Units
Value
Channel
4
See 14 (C) in Groups and channels
(null to query last macro ran in text)
noTe: The response will indicate successful execution of the macro, but it does not guarantee
that each command in the macro was executed.
manUFacTUReR – Manufacturer Identification Label
This command selects/reports the model identification label of the specified channel.
Command Form
: DEVICE manUFacTUReR
argument Type
size
values
Units
Channel
Channel
1
See Groups and channels
Group
Group
1
1, 2, 3, 7
(i, o, m, l)
reserved
unsigned
integer
2
0
label
String
16
1-16 characters
CleAr = clear the label
(null to query in text)
dB
model – Model Identification Label
This command selects/reports the model identification label of the specified channel.
Command Form
: DEVICE model
argument Type
size
values
Units
Channel
Channel
1
See Groups and channels
Group
Group
1
1, 2, 3, 7
(i, o, m, l)
reserved
unsigned
integer
2
0
label
String
16
1-16 characters
CleAr = clear the label
(null to query in text)
dB
maX – Maximum Gain Setting
This command changes or reports back the maximum gain setting for an input, output or assignable processing
block.
Command Form
: DEVICE maX
argument Type
size
values
Units
Channel
Channel
1
See Groups and channels
Group
Group
1
1, 2, 3, 5, 7, 12, 16, 17 (i, o, m, p, l, F, T, r)
Value
Signed Float
2
-65.00 – 20.00
(null to query in text)
dB