Appendix A: Serial Commands 229

macRo – Macro Execution/Reporting

This command executes a specified macro or reports the last macro executed.

Command Form

: DEVICE macRo [Value]

argument Type

size

values

Units

Value

Channel

4

See 14 (C) in Groups and channels
(null to query last macro ran in text)

noTe: The response will indicate successful execution of the macro, but it does not guarantee

that each command in the macro was executed.

manUFacTUReR – Manufacturer Identification Label

This command selects/reports the model identification label of the specified channel.

Command Form

: DEVICE manUFacTUReR [Value]

argument Type

size

values

Units

Channel

Channel

1

See Groups and channels

Group

Group

1

1, 2, 3, 7
(i, o, m, l)

reserved

unsigned
integer

2

0

label

String

16

1-16 characters
CleAr = clear the label
(null to query in text)

dB

model – Model Identification Label

This command selects/reports the model identification label of the specified channel.

Command Form

: DEVICE model [Value]

argument Type

size

values

Units

Channel

Channel

1

See Groups and channels

Group

Group

1

1, 2, 3, 7
(i, o, m, l)

reserved

unsigned
integer

2

0

label

String

16

1-16 characters
CleAr = clear the label
(null to query in text)

dB

maX – Maximum Gain Setting

This command changes or reports back the maximum gain setting for an input, output or assignable processing
block.

Command Form

: DEVICE maX [Value]

argument Type

size

values

Units

Channel

Channel

1

See Groups and channels

Group

Group

1

1, 2, 3, 5, 7, 12, 16, 17 (i, o, m, p, l, F, T, r)

Value

Signed Float

2

-65.00 – 20.00
(null to query in text)

dB