background image

Appendix A: Serial Commands 217

deFaUlT – Default The Unit

Sets the unit to factory defaults. There is no query for this command.

Command Form

: DEVICE deFaUlT

no arguments

delay – Delay Adjust

This command selects/reports the setting of delay time.

Command Form

: DEVICE delay [Value]

argument Type

size

values

Units

Channel

Channel

1

See Groups and channels

Group

Group

1

5 (p)

Value

unsigned Float

2

0.00 – 250.00
(null to query in text)

ms

delaysel – Delay Select

This command selects/reports the delay activation of an assignable processing channel.

Command Form

: DEVICE delaysel [Value]

argument Type

size

values

Units

Channel

Channel

1

See Groups and channels

Group

Group

1

5 (p)

Value

unsigned integer

2

0 = off
1 = on
2 = Toggle
(null to query in text)

devicename – Argument Identification Label

This selects/reports the device Argument identification label of the specific channel.

CommanD Form

: DEVICE devicename [Value]

argument Type

size

values

Units

Channel

Channel

1

See Groups and channels

Group

Group

1

1, 2, 3, 7
(i, o, m, l)

reserved

unsigned integer 2

0

label

String

12

1 – 12 characters
CleAr = clear the label
(null to query in text)

devicesUbType – Sets the Subtype of a Connected Device

This command enables/disables or reports the current type of device connected to an input or output.

Command Form

: DEVICE devicesUbType [Value]

argument Type

size

values

Units

Channel

Channel

1

See Groups and channels

Group

Group

1

1, 2, 3, 7 (i, o, m, l)

Value

unsigned integer

2

(null to query in text)