ClearOne Converge Pro User Manual
Page 243
Appendix A: Serial Commands 239
siGGen – Signal Generator
This command selects/reports of the signal generator activation.
Command Form
: DEVICE siGGen [Channel Group Type Amplitude Frequency]
argument
Type
size
values
Units
Channel
Channel
1
See Groups and channels
(null to query in text)
Group
Group
1
1, 3, 7 (i, m, l)
Type
unsigned integer
2
1 = pink noise
2 = White noise
3 = Tone
Amplitude
Signed Float
4
-60.00 – 20.00
dB
Frequency
unsigned Float
4
Type 1 – 2
0 (null in text)
Hz
Type 3
20.00 – 20000.00
siGGenen – Signal Generator Enable
This command selects/reports of the signal generator activation.
Command Form
: DEVICE siGGenen [Value]
argument
Type
size
values
Units
Value
unsigned integer
4
0 = off
1 = on
2 = Toggle
(null to query in text)
siGGensWeep – Signal Generator Sweep
This command starts the signal generator with a tone and does a sweep. if Repeat is 0, the signal generator will
turn off after the sweep. if Repeat is 1, the signal generator will turn off after signal generator timeout. To stop
the sweep, send a SiGGenen command with a 0. during the sweep, the box will send out updated SiGGen
commands.
Command Form
:
DEVICE siGGensWeep
argument
Type
size
values
Units
Channel
Channel
1
See Groups and channels
Group
Group
1
1, 3, 7 (i, m, l)
Amplitude
Signed Float
2
-60.00 – 20.00
dB
Start
Frequency
unsigned Float
4
20.00 – 20000.00
Hz
end
Frequency
unsigned Float
4
20.00 – 20000.00 (must be greater than the
start)
Hz
increment
Frequency
unsigned Float
4
1.00 – 20000.00
Hz
rate
unsigned integer
2
10 – 2000 ms
Hz
repeat
unsigned integer
2
0 = repeat off
1 = repeat on