Appendix A: Serial Commands 235

pp – Phantom Power

This command selects/reports the setting of phantom power.

Command Form

: DEVICE pp [Value]

argument Type

size

values

Units

Channel

Channel

1

See Groups and channels

Group

Group

1

3 (m)

Value

unsigned integer

2

0 = off
1 = on
2 = Toggle
(null to query in text)

pReseT – Preset Execution/Reporting

This command selects/reports the state of a preset.

Command Form

: DEVICE pReseT [Value]

argument Type

size

values

Units

Channel

Channel

1

0 (Binary)/null (Text) = Query last preset ran
See Groups and channels

Group

Group

1

13 (S)

Value

unsigned integer

2

0 = Set preset state to off
1 = Set state to on and execute if not already on
2 = execute and return state to off
(null to query current state in text)

pRGsTRinG – Program String

This command sets/reports a programmed string.

CommanD Form

: DEVICE pRGsTRinG [Value]

argument Type

size

values

Units

id

unsigned integer

4

0 – 7

Value

String

80

CleAr = Clear current value
1 – 80 Chars
(null to query in text)
Special Characters:
\a = alert
\b = backspace
\f = form feed
\n = new line
\r = carriage return
\t = horizontal tab
\v = vertical tab
\\ = backslash

pTTThReshold – Push to Talk Threshold

This command selects/reports the setting of the push to talk threshold for a microphone.

Command Form

: DEVICE pTTThReshold [Value]

argument Type

size

values

Units

Channel

Channel

1

See Groups and channels

Group

Group

1

3 (m)

Value

Float

2

-100 to 0
(null to query in text)

dB