ClearOne Converge Pro User Manual
Page 227

Appendix A: Serial Commands 223
Gain – Gain Adjustment
This command changes or reports back the gain for a channel.
Command Form
: DEVICE Gain
argument Type
size
values
Units
Channel
Channel
1
See Groups and channels
Group
Group
1
1, 2, 3, 5, 7, 12, 16, 17 (i, o, m, p, l, F, T, r)
Value
Signed
Float
2
-99.90 – 99.90 **
(null to query in text)
dB
Absol / rel
0
A = Absolute
r = relative
null = relative
noTe: Values indicate valid range for entry values only. Actual internal range of the gain stage is
from –65 to 20. Absolute values will be limited to the internal gain range.
GaTe – Gate Status
This command reports the gate status of mics. This command is read only.
Command Form
: DEVICE GaTe [Value]
argument
Type
size
values
Units
Value
Hexadecimal
4
Bits 0 – 7 represent gate status on mics 1 – 8
(null sent in text, Value returned)
Ghold – Gate Hold Time Adjust
This command selects/reports the setting of hold time.
Command Form
: DEVICE Ghold
argument Type
size
values
Units
Channel
Channel
1
See Groups and channels
Group
Group
1
3 (m)
Value
unsigned Float
2
0.10 – 8.00
(null to query in text)
S
Gmode – Gating Mode
This command selects/reports the setting of gating mode.
Command Form
: DEVICE Gmode
argument Type
size
values
Units
Channel
Channel
1
See Groups and channels
Group
Group
1
3 (m)
Value
unsigned integer
2
1 = Auto
2 = manual on
3 = manual off
(null to query in text)