Gain – Gain Adjustment

This command changes or reports back the gain for a channel.

Command Form

: DEVICE Gain [Value] [Absol/rel]

argument Type

size

values

Units

Channel

Channel

1

See Groups and channels

Group

Group

1

1, 2, 3, 5, 7, 12, 16, 17 (i, o, m, p, l, F, T, r)

Value

Signed
Float

2

-99.90 – 99.90 **
(null to query in text)

dB

Absol / rel

0

A = Absolute
r = relative
null = relative

noTe: Values indicate valid range for entry values only. Actual internal range of the gain stage is

from –65 to 20. Absolute values will be limited to the internal gain range.

GaTe – Gate Status

This command reports the gate status of mics. This command is read only.

Command Form

: DEVICE GaTe [Value]

argument

Type

size

values

Units

Value

Hexadecimal

4

Bits 0 – 7 represent gate status on mics 1 – 8
(null sent in text, Value returned)

Ghold – Gate Hold Time Adjust

This command selects/reports the setting of hold time.

Command Form

: DEVICE Ghold [Value]

argument Type

size

values

Units

Channel

Channel

1

See Groups and channels

Group

Group

1

3 (m)

Value

unsigned Float

2

0.10 – 8.00
(null to query in text)

S

Gmode – Gating Mode

This command selects/reports the setting of gating mode.

Command Form

: DEVICE Gmode [Value]

argument Type

size

values

Units

Channel

Channel

1

See Groups and channels

Group

Group

1

3 (m)

Value

unsigned integer

2

1 = Auto
2 = manual on
3 = manual off