Stainless steel, N₂ plasma / h₂o shield, This art is for reference only – Tweco Ultra-Cut Torch Data User Manual
Page 9

Manual 0-4828
Rev BA
8-9
TORCH DATA for Ultra-Cut
Stainless Steel
Flow Rates
30A
N₂ (SLPM / SCFH)
H₂O (GPH / LPH)
Preflow
9 / 19
5 / 19
N₂ Plasma / H₂O Shield
Cutflow
28 / 59
5 / 19
Shield Cup
Shield Cap
Shield Gas
Distributor
Tip
Plasma Gas Distributor
Electrode
Cartridge
21-1016
21-1033
21-1274
21-1059
21-1045
21-1077
21-1020
GCM-2010
SC-3000 Torch Height Control (THC)
Basic THC
CNC Control
Material
Thickness
Pre Flow
Pressure
(N₂)
Cut Flow Rates / Pressures
Arc
Voltage Cut Height
THC
Pierce
Delay
Pierce
Ignition
Height
Elevation
Height
Control
Delay
Pierce
Height
without
Elevation
Travel
Speed
CNC
Motion
Delay
Max Kerf Width
@ Rec. Speed
Plasma (N₂) Shield (H₂O)
ga
(in)
inch
(psi)
Ball (psi) Ball (psi)* (Volts) (in) ±0.005 (sec)
(in)
(in)
(sec)
(in)
(ipm)
(sec)
(in)
26
-
0.019
90
75
120
4
55
91
0.020
0.0
0.040 0.030
0.5
0.040
600
0.0
0.047
24
-
0.025
90
64
120
4
55
97
0.020
0.0
0.040 0.030
0.5
0.040
440
0.0
0.045
22
-
0.031
90
50
120
4
55
95
0.020
0.0
0.040 0.030
0.5
0.040
420
0.0
0.045
20
-
0.038
90
60
120
5
55
105
0.020
0.1
0.050 0.040
0.4
0.050
300
0.1
0.044
18
-
0.050
90
60
120
5
55
78
0.030
0.1
0.050 0.040
0.4
0.050
250
0.1
0.035
16
-
0.063
90
60
120
5
55
85
0.050
0.2
0.060 0.040
0.4
0.060
205
0.2
0.044
GCM-2010
SC-3000 Torch Height Control (THC)
Basic THC
CNC Control
Material
Thickness
Pre Flow
Pressure
(N₂)
Cut Flow Rates / Pressures
Arc
Voltage Cut Height
THC
Pierce
Delay
Pierce
Ignition
Height
Elevation
Height
Control
Delay
Pierce
Height
without
Elevation
Travel
Speed
CNC
Motion
Delay
Max Kerf Width
@ Rec. Speed
Plasma (N₂) Shield (H₂O)
(mm)
(Bar)
Ball (Bar) Ball (Bar)* (Volts) (mm) ±0.1 (sec)
(mm)
(mm)
(sec)
(mm)
(mm/
min)
(sec)
(mm)
0.6
6.2
67
8.3
4
3.8
96
0.5
0.0
1.0
0.8
0.5
1.0
12110
0.0
1.2
0.8
6.2
51
8.3
4
3.8
96
0.5
0.0
1.0
0.8
0.5
1.0
10450
0.0
1.1
1
6.2
60
8.3
5
3.8
102
0.5
0.1
1.3
1.0
0.4
1.3
7480
0.1
1.1
1.5
6.2
60
8.3
5
3.8
83
1.1
0.2
1.4
1.0
0.4
1.4
5550
0.2
1.0
2
6.2
60
8.3
5
3.8
93
1.9
0.3
1.8
1.0
0.4
1.8
3820
0.3
1.4
Marking
Pre Flow
Pressure
(N₂)
Marking Flow Rates /
Pressures
Arc
Voltage
Marking
Height
Pierce Ignition Height
THC and CNC
Delay
Control
Delay
Travel
Speed
Marking quality
degrades as
thickness
decreases.
16A Arc Current
Plasma (N₂)
Shield (N₂)
Burn-through may
happen for thicknesses
< 1/16” (0.063”) /
1.6 mm.
(psi) /
(Bar)
Ball (psi) /
(Bar)
Ball (psi) /
(Bar) (Volts)
(in) ±0.005 /
(mm) ±0.1
(in) ±0.005 / (mm) ±0.1
(sec)
(sec)
(ipm) /
(mm/ min)
20 / 1.4
20
40 /
2.8
70
80 /
5.5
93
0.100 / 2.5
0.100 / 2.5
0
0.4
300 /
7620
BOLD TYPE indicates maximum piercing parameters.
* Pressure of the water supply line should be regulated by customer pressure regulator.
Note 1: Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the ohmic sensing circuit.
Note 2: Water source used for shield must be demineralized.
Electrode
Shield Cap
Tip
Shield Gas
Distributor
Plasma Gas
Distributor
Cartridge
Shield Cup
This Art Is For Reference ONLY
Art # A-07958_AB