Table 5-52 Standard Mode Instance Attributes
Table 5-53 Standard Mode Common Services
153
Get/
Set
NV
Is
Calibration
Disabled
BOOL
Option to turn off
measurement calibration.
FALSE for
calibrated
data (default),
TRUE for raw
data
(diagnostic).
Default:
FALSE
Hidden
attribute for
diagnostic
purposes only!
Attrib
Rule
NV
Name
Data
Type
Description
Semantics
of Value
Attrib Rule NV
Name
Data
Type
Description
Semantics
of Value
1
Get/
Set
NV
Fundamental
Selection
STRUCT
of:
Fundame
ntal
Fundamental frequency
and harmonic
component selection.
See the
Fundamenta
l structure.
2
Get
V
Num
Measurements
USINT
The number of voltage
and current harmonic
component
measurements
contained in the
following array.
Value range:
0-16
3
Get
V
Measurements
Array of:
STRUCT
of:
VIMeas
Voltage and current
harmonic component
measurements.
See VIMeas
structure.
4
Get
V
Num Intermods
USINT
The number of
intermodulation products
contained in the
following array.
Value range:
0-6
5
Get
V
Intermods
Array of:
STRUCT
of:
VIMeas
Voltage and current
intermodulation product
measurements.
See VIMeas
structure.
Service
Code
Class Instance
Service Name
Description of Service
14 (0x0E)
Yes
Yes
Get_Attribute_Single Returns the contents of the
specified attribute.
16 (0x10)
Yes
Yes
Set_Attribute_Single
Modifies an attribute.