Bird Technologies BDS-Manual User Manual
Page 53
39
Code
Description
Action
OOOO
No power applied.
Reboot the receiver by
disconnecting power and then
reconnecting power.
RRRR
CPU exception to unknown vector.
OROR
RAM Failure
ORRO
Bootloader checksum failure.
ORRR
Kernel failure.
OOOR
CPU Fault – Illegal instruction.
OORO
CPU Fault – Address error.
OORR
CPU Fault – Unimplemented A-line.
OROO
CPU Fault – Unimplemented F-line.
YYOO
Bootloader RAM test pass.
These LED codes are normally
displayed during receiver boot-up.
If the BDS reports any one of
these codes for an indefinite
amount of time reboot the
receiver by disconnecting power
and then reconnecting power.
YYYO
Bootloader loaded.
YYYY
Bootloader running.
GYYY
Operating system loaded.
GGYY
Operating system running.
GGGY
Main applications running, but calibration
data has not been loaded (the probe is
disconnected).
Attach the probe to the receiver
and wait approximately 1 minute.
GGGG
System is ready with all components
connected and all calibration data loaded.
No action. Ready for use.
YGGY
Loading FPGA image.
This code is normally displayed
during receiver boot-up. Update
the firmware if the BDS reports
this code for an indefinite
amount of time.
RYYY
DSP error – general or initialization failure.
Update the firmware.
YRYY
DSP error – DCM lock failure.
Reboot the receiver by
disconnecting power and then
reconnecting power.
YYRY
DSP error – PLL lock failure.
YRRY
DSP error – heartbeat flat-line. DSP stopped
producing data.
YYYR
Fatal application software error –
unrecoverable exception caught.
Update the firmware and/or
reboot the receiver by
disconnecting power and then
reconnecting power.
RYRY
Fatal application software error – assertion
failure.
YRYR
Fatal application software error –
segmentation fault.
YYRR
Fatal application software error – bus error.