beautypg.com

Time plot view, Figure 8 data viewed in time plot format, Reconstructed waveform view – Bird Technologies BDS-Manual User Manual

Page 35: Figure 9 data viewed as a waveform, Time plot view reconstructed waveform view

background image

21

Vrms (Volts) - RMS voltage reading.

Irms (Amp) - RMS current reading.

Z (Ohms) - Impedance magnitude in Ohms. Note: Z=V/I.

Phase (Deg) - The phase in degrees.

R (Ohms) – Resistance in Ohms - the real part of impedance (in rectangular coordinates).

jX (Ohms) – Reactance in Ohms - the imaginary part of impedance (in rectangular coordinates).

P (Watts) - Power in Watts.

Note:

Rel P (dBc) - Power relative to the carrier in dBc.

Rel Ph – Phase relative to the fundamental in degrees.

Note: This is only reported if relative phase is enabled. See “Enable relative phase measurements” in Stan-
dard Tracking Mode Options.

Attn V (dB) - The attenuation applied (in dB) to the voltage channel during this frequency measurement.

Attn I (dB) - The attenuation applied (in dB) to the current channel during this frequency measurement.

Time Plot View

Figure 8 Data Viewed in Time Plot Format

Note: The Time Plot view displays each dataset over time. The dataset number is displayed on the X-axis.

Reconstructed Waveform View

Figure 9 Data Viewed As a Waveform

Note: The Waveform view displays a single waveform of a fundamental tone constructed from the har-
monic components captured. Waveform reconstruction is only possible if relative phase is enabled. See
“Enable relative phase measurements” in Standard Tracking Mode Options.

P

V

rms

I

rms

×

(

)

Phase

(

)

cos

=