beautypg.com

Assembly object – class code: 4 (04hex), Table 5-17 assembly class attributes (instance 0), Assembly object – class code: 4 (04 – Bird Technologies BDS-Manual User Manual

Page 72

background image

58

Assembly Object – Class Code: 4 (04

HEX

)

Table 5-17 Assembly Class Attributes (Instance 0)

Attrib

Rule

NV

Name

Data

Type

Description

Value

1

Get

NV

Revision

UINT

Revision level of this
object.

2

2

Get

NV

Max Instance

UINT

Maximum instance
number.

101

100

Set/
Set

V

Input Assembly
Instance ID

USINT Selected input

assembly instance
ID. Changing the
value of this attribute
will also change the
value of the “Input
Assembly Size”
attribute.

One of the
following:
100 (64

HEX

)

101 (65

HEX

)

Default: 101

101

Get

V

Input Assembly
Size

UINT

Selected input
assembly size in
bytes – the number of
bytes produced by
the BDS for the
selected assembly.
Setting the “Input
Assembly Instance
ID” attribute will
change this value.
Setting the “Num
Fundamentals” or
“Fundamental
Selection” attributes
from the “Standard
Mode” class will also
change this value.

Based on the
Input
Assembly
Instance ID
attribute and
the Standard
Mode object
configuration.

Inst 100: 10-
2760
Inst 101: 96

Default: 96
bytes

102

Get

V

Num
Measurements

USINT The total number of V

& I measurements
contained in the
selected input
assembly instance.
This value is based
on the “Standard
Mode” configuration.

Based on
Standard
Mode object
configuration.
Min: 0
Max: 110

Default: 0

103

Get

V

System Status

DWOR
D

BDS system status
bitfield.
Note: Changing any
attributes in the
“Standard Mode” or
“Application” classes
will reset the status
(to a value of 0).

See “BDS
System Status
Bitfield” in the
Appendix for
status bit
descriptions.
A value of 0
means nothing
to report.

104

Get

V

Timestamp

DATE_
AND_
TIME

Data acquisition
timestamp.