Power interconnect diagrams, S b.1 and b.2 f – Rockwell Automation 1394 SERCOS Interface Multi-Axis Motion Control System Installation Manual User Manual
Page 119
Publication 1394-IN002B-EN-P — February 2004
Interconnect Diagrams
B-3
Power Interconnect
Diagrams
The power interconnect wiring for the 1394 SERCOS interface system
module is shown in the figures below.
Figure B.1
1394C-SJT05-D or -SJT10-D Interconnect Diagram
Figure B.2
1394C-SJT22-D Interconnect Diagram
Drive System OK
Relay Output 3
Relay Output 2
Relay Output 1
Relay Output 0
A
J4
J5
1
2
3
4
5
6
7
8
9
10
W1
W2
DC+
INT
COL
PE
W
V
U
J6
LOGIC POWER
& SIGNALS
DC BUS POS.
DC BUS NEG.
SLIDER INTERCONNECT
1394 SERCOS interface SYSTEM MODULE
1394C-SJT05-D or -SJT10-D
DC MINUS BUS
Refer to Chapter 3 for
ground jumper instructions.
Note 7
Relay Outputs
Connector
* INDICATES USER-SUPPLIED COMPONENT
Three-Phase Input
360-380V ac RMS
Bonded Cabinet Ground Bu
Logic Power
Connector
Shunt Power
Connector
Three-Phase
AC Line Filter
Note 3
Input Fusing*
Input Fusing *
M1*
Bonded Cabinet
Ground Bus*
Input Power
Connector
24V ac RMS or
24V dc (non-polarized)
External Shunt
Connections (optional)
Note 10
System Module
Single Point Bond Bar
Brake cable (2090-UXNBMP-18Sxx) for
MP-Series and 1326AB (M2L/S2L) motors
(refer to Brake Interconnect Diagrams
beginning on page B-14).
To TB2-1 and TB2-2 for
1326AB/AS (resolver) motors.
(refer to Thermal Switch Interconnect Diagrams
beginning on page B-9).
STOP*
START*
CR1*
CR1*
CR1*
M1*
Refer to Attention statement (Note 8)
24V ac/dc
or
120V ac
50/60 Hz
to 1394 Axis Module PE1 terminal
Drive System OK
Relay Output 3
Relay Output 2
Relay Output 1
Relay Output 0
J4
J5
1
2
3
4
5
6
7
8
9
10
W1
W2
DC+
COL
PE
W
V
U
J6
A
LOGIC POWER
& SIGNALS
DC BUS POS.
DC BUS NEG.
SLIDER INTERCONNECT
1394 SERCOS interface SYSTEM MODULE
1394C-SJT22-D
DC MINUS BUS
Relay Outputs
Connector
Bonded Cabinet Ground Bus
Logic Power
Terminal Blocks
Shunt Power
Terminal Blocks
Input Fusing*
Input Fusing *
Bonded Cabinet
Ground Bus*
Input Power
Terminal Blocks
External Shunt
Connections
Note 11
System Module
Single Point Bond Bar
STOP*
START*
CR1*
CR1*
CR1*
M1*
24V ac/dc
or
120V ac
50/60 Hz
Refer to Chapter 3 for
ground jumper instructions.
Note 7
Three-Phase Input
360-380V ac RMS
Three-Phase
AC Line Filter
Note 3
M1*
Notes 4, 5
24V ac RMS or
24V dc (non-polarized)
Notes 1, 2
Brake cable (2090-UXNBMP-18Sxx) for
MP-Series and 1326AB (M2L/S2L) motors
(refer to Brake Interconnect Diagrams
beginning on page B-14).
To TB2-1 and TB2-2 for
1326AB/AS (resolver) motors.
(refer to Thermal Switch Interconnect
Diagrams beginning on page B-9).
Refer to Attention statement (Note 8)
Notes 4, 9
* INDICATES USER-SUPPLIED COMPONENT
to 1394 Axis Module PE1 terminal