Operation and Programming
Chapter 5
5-6
5. An auxiliary interlock wired to the Control and Signal Wiring
Terminal Block will stop the drive and display either
AU
or
A5
, as set by Parameter 21.
LJ
To indicate the local jog function has been selected.
EE
To indicate:
1. Drive start, jog, speed and forward/reverse is controlled by
external devices or logic wired to the Control and Signal Wiring
Terminal Block.
2. An external stop signal wired to the Control and Signal Wiring
Terminal Block will stop the drive as programmed by
Parameters 11-14.
3. An auxiliary interlock wired to the Control and Signal Wiring
Terminal Block will stop the drive and display either
AU
or
A5
, as set by Parameter 21.
4. The Local Control Panel stop pushbutton will allow the drive to
coast-to-stop and display
OP
.
EL
To indicate:
1. Drive start, jog and forward/reverse is controlled by external
devices or logic wired to the Control and Signal Wiring
Terminal Block.
2. Drive speed is controlled from the Local Control Panel.
3. An external stop signal wired to the Control and Signal Wiring
Terminal Block will stop the drive as programmed by
Parameters 11-14.
4. The Local Control Panel stop pushbutton will allow the drive to
coast-to-stop and display
OP
.
5. An auxiliary interlock wired to the Control and Signal Wiring
Terminal Block will stop the drive and display either
AU
or
A5
, as set by Parameter 21.
EJ
To indicate an external jog signal is being sent.